Anil K Saxena1, B R Panhotra, Mohammed Naguib.
Abstract
Gram-negative septicemia due to central venous catheter-related infection is a leading cause of mortality and morbidity among patients who undergo hemodialysis. Antibiotic-heparin locks are valuable for preserving access sites and lowering the cost and inconvenience associated with central venous catheter replacement and surgical interventions. The optimal duration of use of an antibiotic-heparin lock is unknown. Prolonged use of an amikacin-heparin lock may lead to severe irreversible sensory-neural hearing loss. Patients at risk for this complication should be monitored for its emergence to facilitate early detection. A 43-year-old man with diabetic end-stage renal disease received hemodialysis through a permanent catheter. After 16 weeks of using an amikacin-heparin lock, he suddenly developed sensory-neural hearing loss of 40 dB, which affected high frequencies. His condition progressed relentlessly within 1 week despite immediate discontinuation of the amikacin-heparin lock. The patient developed severe irreversible hearing loss below 80 dB for both high and low frequencies.Entities:
Mesh:
Substances:
Year: 2002 PMID: 11794420 DOI: 10.1592/phco.22.1.105.33507
Source DB: PubMed Journal: Pharmacotherapy ISSN: 0277-0008 Impact factor: 4.705