Literature DB >> 11793287

[B-flow and contrast medium-enhanced power Doppler (Optison(R))--preoperative diagnosis of high-grade stenosis of the internal carotid artery].

E M Jung1, R Kubale, D A Clevert, R Lutz, N Rupp.   

Abstract

PURPOSE: To improve sonographic diagnosis of high-grade stenosis of the internal carotid artery (ICA) by vascular sonography in "B-flow"-mode and in contrast medium (Optison(R))-enhanced power Doppler (PD).
MATERIAL AND METHODS: 88 patients suspected of a high-grade stenosis of the extracranial ICA were examined by independent examiners with color-coded Doppler (CCD), B-flow and PD to compare the methods for morphology and degree of stenosis. In 21 cases contrast medium was used in PD. Sonographic results of all 88 patients were compared with selective angiography (DSA), in 53 cases with operative findings.
RESULTS: A complete occlusion was found in 9 patients and a 50 - 70 % degree non-exulcerated stenosis in 26 cases. 53 of 88 patients presented findings in both sonography and DSA leading to operation of the ICA. Among these 47 had a stenosis > 70 % and 6 a stenosis of 60 - 70 % with exulcerated plaques. Even a small dose of contrast medium (0.3 ml) gave a significant signal increase in PD improving flow detection even in extensive vascular calcification. In both the early phase (up to the first minute p. i.) flow contrast was optimal and without significant artifacts. Thus, the extent and the morphology of the stenosis was better appreciated. Hypoechogenic plaques, ulcerations and thrombi are as easily recognized by B-flow as flow in preocclusive stenosis, free of vibration and blooming artifacts. This gave a better correlation with DSA and a higher diagnostic accuracy in grading a stenosis than CCD and PD. Circular calcifications or vessel kinking made diagnosis of flow more difficult.
CONCLUSION: B-flow allows a reliable diagnosis of the degree of stenosis of ICA and a better appreciation of plaque morphology than CCD. In some cases with extensive calcifications contrast medium-enhanced PD is able to detect better intrastenotic flow. Only small quantities of contrast medium (Optison(R)) are required.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11793287     DOI: 10.1055/s-2002-19548

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  8 in total

1.  Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography.

Authors:  D-A Clevert; N Rupp; M Reiser; E M Jung
Journal:  Eur Radiol       Date:  2004-09-24       Impact factor: 5.315

2.  [Significance of Doppler ultrasound procedures for diagnosis of carotid stenoses].

Authors:  R Kubale; C Arning
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

Review 3.  [Ultrasound diagnosis of vascular complications following transfemoral puncture].

Authors:  D A Clevert; R Kubale; T I Strautz; P M Flach; C Trumm; R T Hoffmann; M Reiser
Journal:  Radiologe       Date:  2006-07       Impact factor: 0.635

Review 4.  [Value of vascular ultrasound in the evaluation of hemodialysis fistulas].

Authors:  D-A Clevert; E M Jung; R Kubale; T Waggershauser; M Stickel; G Schulte-Altedorneburg; R Kopp; M Reiser
Journal:  Radiologe       Date:  2008-03       Impact factor: 0.635

5.  [Current developments in vascular ultrasound].

Authors:  A Horng; M Reiser; D-A Clevert
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

6.  Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow.

Authors:  E M Jung; R Kubale; G Ritter; M T Gallegos; K-P Jungius; N Rupp; D-A Clevert
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

Review 7.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11

8.  Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography.

Authors:  D-A Clevert; T Johnson; E M Jung; D-A Clevert; P M Flach; T I Strautz; G Ritter; M T Gallegos; R Kubale; C Becker; M Reiser
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 7.034

  8 in total