Literature DB >> 11788206

Coronary in-stent restenosis: current status and future strategies.

Harry C Lowe1, Stephen N Oesterle, Levon M Khachigian.   

Abstract

In-stent restenosis (ISR) is a novel pathobiologic process, histologically distinct from restenosis after balloon angioplasty and comprised largely of neointima formation. As percutaneous coronary intervention increasingly involves the use of stents, ISR is also becoming correspondingly more frequent. In this review, we examine the available studies of the histology and pathogenesis of ISR, with particular reference to porcine and other animal models. An overview of mechanical treatments is then provided, which includes PTCA, directional coronary atherectomy and high speed rotational atherectomy. Radiation-based therapies are discussed, including a summary of current problems associated with this modality of treatment. Finally, novel strategies for the prevention of ISR are addressed, including novel developments in stents and stent coatings, conventional drugs, nucleic acid-based drugs and gene transfer. Until recently, limited pharmacologic and mechanical treatment options have been available for both treatment and prevention of ISR. However, recent advances in gene modification and gene transfer therapies and, more particularly, in local stent-based drug delivery systems make it conceivable that the incidence of ISR will now be seriously challenged.

Mesh:

Year:  2002        PMID: 11788206     DOI: 10.1016/s0735-1097(01)01742-9

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  58 in total

1.  Is surgery still the preferred option for coronary revascularisation in diabetics with multivessel coronary disease?

Authors:  A Kapur; I S Malik
Journal:  Heart       Date:  2002-05       Impact factor: 5.994

Review 2.  Drug-eluting stents for cardiovascular disorders.

Authors:  Juan F Granada; Grzegorz L Kaluza; Albert Raizner
Journal:  Curr Atheroscler Rep       Date:  2003-07       Impact factor: 5.113

3.  Impact of intima re-intrusion and expansion within 100 minutes on late lumen loss in percutaneous coronary intervention for diffuse in-stent restenosis.

Authors:  R Iijima; Y Ikari; T Tsunoda; M Nakamura; K Hara; T Yamaguchi
Journal:  Heart       Date:  2004-09       Impact factor: 5.994

4.  In vitro study of role of trace amount of Cu release from Cu-bearing stainless steel targeting for reduction of in-stent restenosis.

Authors:  Ling Ren; Lu Xu; Jingwen Feng; Yang Zhang; Ke Yang
Journal:  J Mater Sci Mater Med       Date:  2012-02-23       Impact factor: 3.896

5.  The pharmacokinetics of Biolimus A9 after elution from the BioMatrix II stent in patients with coronary artery disease: the Stealth PK Study.

Authors:  Miodrag C Ostojic; Zoran Perisic; Dragan Sagic; Robert Jung; Yan-Ling Zhang; Jamie Bendrick-Peart; Ronald Betts; Uwe Christians
Journal:  Eur J Clin Pharmacol       Date:  2010-10-09       Impact factor: 2.953

6.  Manganese superoxide dismutase inhibits neointima formation through attenuation of migration and proliferation of vascular smooth muscle cells.

Authors:  Jia-Ning Wang; Ning Shi; Shi-You Chen
Journal:  Free Radic Biol Med       Date:  2011-10-24       Impact factor: 7.376

7.  Superiority of sirolimus eluting stent compared with intracoronary beta radiation for treatment of in-stent restenosis: a matched comparison.

Authors:  E Iofina; P W Radke; P Skurzewski; P K Haager; R Blindt; K-C Koch; P Hanrath; J vom Dahl; R Hoffmann
Journal:  Heart       Date:  2005-03-29       Impact factor: 5.994

8.  Unconstrained recovery characterization of shape-memory polymer networks for cardiovascular applications.

Authors:  Christopher Michael Yakacki; Robin Shandas; Craig Lanning; Bryan Rech; Alex Eckstein; Ken Gall
Journal:  Biomaterials       Date:  2007-02-02       Impact factor: 12.479

9.  Bisphosphonate-mediated gene vector delivery from the metal surfaces of stents.

Authors:  Ilia Fishbein; Ivan S Alferiev; Origene Nyanguile; Richard Gaster; John M Vohs; Gordon S Wong; Howard Felderman; I-Wei Chen; Hoon Choi; Robert L Wilensky; Robert J Levy
Journal:  Proc Natl Acad Sci U S A       Date:  2005-12-21       Impact factor: 11.205

10.  Disappearance of a small intracranial aneurysm as a result of vessel straightening and in-stent stenosis following use of an Enterprise vascular reconstruction device.

Authors:  Koichiro Takemoto; Satoshi Tateshima; Sachin Rastogi; Nestor Gonzalez; Reza Jahan; Gary Duckwiler; Fernando Vinuela
Journal:  BMJ Case Rep       Date:  2013-01-17
View more