Literature DB >> 11779012

Can MR measurement of renal artery flow and renal volume predict the outcome of percutaneous transluminal renal angioplasty?

C A Binkert1, J F Debatin, E Schneider, J Hodler, S G Ruehm, M Schmidt, U Hoffmann.   

Abstract

PURPOSE: Predicting therapeutic benefit from percutaneous transluminal renal angioplasty (PTRA) in patients with renal artery stenosis (RAS) remains difficult. This study investigates whether magnetic resonance (MR)-based renal artery flow measurements relative to renal parenchymal volume can predict clinical outcome following PTRA.
METHODS: The data on 23 patients (13 men, 10 women; age range 47-82 years, mean age 64 years) were analyzed. The indication for treatment was hypertension (n = 18) or renal insufficiency (n = 5). Thirty-four cases of RAS were identified: bilateral disease was manifest in 11 and unilateral disease in 12 patients. The MR imaging protocol included a breath-hold, cardiac-gated cine phase-contrast sequence for renal flow measurement and a fast multiplanar spoiled gradient-echo sequence for renal volume measurement. MR measurements were performed on the day prior to and the day following PTRA. Clinical success was defined as (a) a reduction in diastolic blood pressure > 15% or (b) a reduction in serum creatinine > 20%. Kidneys were categorized as normal volume or low volume. A renal flow index (RFI) was calculated by dividing the renal flow (ml/min) by the renal volume (cm3).
RESULTS: Clinical success was observed in patients. Twelve patients did not benefit from angioplasty. Normal kidney volume was seen in 10 of 11 responders and in 8 of 12 nonresponders, resulting in a sensitivity of 91%, specificity of 33%, a positive predictive value (PPV) of 56% and a negative predictive value (NPV) of 80%. A RFI below a threshold of 1.5 ml/min/cm3 predicted successful outcome with 100% sensitivity, 33% specificity, 58% PPV, and 100% NPV. The combination of normal renal volume and a RFI below 1.5 ml/min/cm3 identified PTRA responders with a sensitivity of 91%, a specificity of 67%, a PPV of 71%, and a NPV of 89%. PTRA resulted in a greater increase in renal flow in responders compared with nonresponders (p < 0.001).
CONCLUSION: A combination of cine phase-contrast MR renal flow and parenchymal volume measurements enables identification of patients benefiting from PTRA with a high sensitivity and NPV, but only moderate specificity and PPV.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11779012     DOI: 10.1007/s00270-001-0005-y

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  5 in total

Review 1.  Contemporary imaging techniques for the diagnosis of renal artery stenosis.

Authors:  T Leiner; M W de Haan; P J Nelemans; J M A van Engelshoven; G B C Vasbinder
Journal:  Eur Radiol       Date:  2005-06-28       Impact factor: 5.315

2.  Measurement of renal dimensions in vivo: A critical appraisal.

Authors:  H Krishna Moorthy; P Venugopal
Journal:  Indian J Urol       Date:  2011-04

3.  Need for a nomogram of renal sizes in the Indian population- findings from a single centre sonographic study.

Authors:  Prakash Muthusami; Ramesh Ananthakrishnan; Poyyamoli Santosh
Journal:  Indian J Med Res       Date:  2014-05       Impact factor: 2.375

Review 4.  Phase-contrast magnetic resonance imaging to assess renal perfusion: a systematic review and statement paper.

Authors:  Giulia Villa; Steffen Ringgaard; Ingo Hermann; Rebecca Noble; Paolo Brambilla; Dinah S Khatir; Frank G Zöllner; Susan T Francis; Nicholas M Selby; Andrea Remuzzi; Anna Caroli
Journal:  MAGMA       Date:  2019-08-17       Impact factor: 2.310

Review 5.  Renovascular hypertension: an update.

Authors:  William J Elliott
Journal:  J Clin Hypertens (Greenwich)       Date:  2008-07       Impact factor: 3.738

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.