Literature DB >> 11778883

Assessment of heavy metal bioavailability using Escherichia coli zntAp::lux and copAp::lux-based biosensors.

K B Riether1, M A Dollard, P Billard.   

Abstract

To determine the amount of metals detectable by bacteria, two plasmids were constructed in which the metal-inducible zntA and copA promoters from Escherichia coli were fused to a promoterless Vibrio fischeri luxCDABE operon. The luminescence response of E. coli bearing these constructs was studied as a function of the concentration of several heavy metals and was shown to be influenced by cell growth phase. The zntAp::lux fusion is induced mainly by salts of cadmium, lead, mercury and zinc, with significant induction by other metal ions, whereas the specificity of copA induction is restricted to copper and silver. In optimized assay conditions, metals could be detected at threshold concentrations ranging from nanomolar to micromolar, with maximal induction observed after only 60-100 min incubation. The ability of these biosensor strains to distinguish bioavailable quantities of metals in a sample makes them good candidates as useful tools to monitor metal contamination in environmental samples.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11778883     DOI: 10.1007/s00253-001-0852-0

Source DB:  PubMed          Journal:  Appl Microbiol Biotechnol        ISSN: 0175-7598            Impact factor:   4.813


  22 in total

1.  Spatial analysis of antibiotic resistance along metal contaminated streams.

Authors:  R Cary Tuckfield; J Vaun McArthur
Journal:  Microb Ecol       Date:  2008-05       Impact factor: 4.552

2.  Identification of a copper-responsive promoter and development of a copper biosensor in the soil bacterium Achromobacter sp. AO22.

Authors:  Shee Ping Ng; Enzo A Palombo; Mrinal Bhave
Journal:  World J Microbiol Biotechnol       Date:  2012-03-06       Impact factor: 3.312

Review 3.  Are luminescent bacteria suitable for online detection and monitoring of toxic compounds in drinking water and its sources?

Authors:  Marjolijn Woutersen; Shimshon Belkin; Bram Brouwer; Annemarie P van Wezel; Minne B Heringa
Journal:  Anal Bioanal Chem       Date:  2010-11-09       Impact factor: 4.142

4.  Advances in characterizing microbial community change and resistance upon exposure to lead contamination: Implications for ecological risk assessment.

Authors:  S Elizabeth George; Yongshan Wan
Journal:  Crit Rev Environ Sci Technol       Date:  2019-12-23       Impact factor: 12.561

5.  Improving the sensitivity of bacterial bioreporters for heavy metals.

Authors:  Anu Hynninen; Karmen Tönismann; Marko Virta
Journal:  Bioeng Bugs       Date:  2009-12-02

Review 6.  Recent advances in bacterial biosensing and bioremediation of cadmium pollution: a mini-review.

Authors:  Chang-Ye Hui; Yan Guo; Lisa Liu; Juan Yi
Journal:  World J Microbiol Biotechnol       Date:  2021-12-01       Impact factor: 3.312

7.  Bioluminescent bioreporter for assessment of arsenic contamination in water samples of India.

Authors:  Pratima Sharma; Shahzada Asad; Arif Ali
Journal:  J Biosci       Date:  2013-06       Impact factor: 1.826

8.  LuxCDABE--transformed constitutively bioluminescent Escherichia coli for toxicity screening: comparison with naturally luminous Vibrio fischeri.

Authors:  Imbi Kurvet; Angela Ivask; Olesja Bondarenko; Mariliis Sihtmäe; Anne Kahru
Journal:  Sensors (Basel)       Date:  2011-08-11       Impact factor: 3.576

Review 9.  The evolution of the bacterial luciferase gene cassette (lux) as a real-time bioreporter.

Authors:  Dan Close; Tingting Xu; Abby Smartt; Alexandra Rogers; Robert Crossley; Sarah Price; Steven Ripp; Gary Sayler
Journal:  Sensors (Basel)       Date:  2012-01-11       Impact factor: 3.576

10.  Highly sensitive, highly specific whole-cell bioreporters for the detection of chromate in environmental samples.

Authors:  Rita Branco; Armando Cristóvão; Paula V Morais
Journal:  PLoS One       Date:  2013-01-11       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.