Literature DB >> 11777643

Investigation of the added value of high-energy electrons in intensity-modulated radiotherapy: four clinical cases.

Erik W Korevaar1, Henk Huizenga, Johan Löf, Joep C Stroom, Jan Willem H Leer, Anders Brahme.   

Abstract

PURPOSE: Intensity-modulated radiotherapy (IMRT) with photon beams is currently pursued in many clinics. Theoretically, inclusion of intensity- and energy-modulated high-energy electron beams (15-50 MeV) offers additional possibilities to improve radiotherapy treatments of deep-seated tumors. In this study the added value of high-energy electron beams in IMRT treatments was investigated. METHODS AND MATERIALS: In a comparative treatment planning study, conventional treatment plans and various types of IMRT plans were constructed for four clinical cases (cancer of the bladder, pancreas, chordoma of the sacrum, and breast). The conventional plans were used for the actual treatment of the patients. The IMRT plans were optimized using the Orbit optimization code (Löf et al., 2000) with a radiobiologic objective function. The IMRT plans were either photon or combined electron and photon beam plans, with or without dose homogeneity constraints assuming standard or increased radiosensitivities of organs at risk.
RESULTS: Large improvements in expected treatment outcome are found using IMRT plans compared to conventional plans, but differences in tumor control probability (TCP) and normal tissue complication probabilities (NTCP) values between IMRT plans with and without electrons are small. However, the use of electrons improves the dose-volume histograms for organs at risk, especially at lower dose levels (e.g., 0-40 Gy).
CONCLUSIONS: This preliminary study indicates that addition of higher energy electrons to IMRT can only marginally improve treatment outcome for the selected cases. The dose-volume histograms of organs at risk show improvements for IMRT with higher energy electrons, which may reduce tumor induction but does not substantially reduce NTCP.

Entities:  

Mesh:

Year:  2002        PMID: 11777643     DOI: 10.1016/s0360-3016(01)02689-x

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Implementation and experimental validation of a robust hybrid direct aperture optimization approach for mixed-beam radiotherapy.

Authors:  Emily Heath; Silvan Mueller; Gian Guyer; Alisha Duetschler; Olgun Elicin; Daniel Aebersold; Michael K Fix; Peter Manser
Journal:  Med Phys       Date:  2021-10-14       Impact factor: 4.506

2.  Comparisons of treatment optimization directly incorporating random patient setup uncertainty with a margin-based approach.

Authors:  Joseph A Moore; John J Gordon; Mitchell S Anscher; Jeffrey V Siebers
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071