Literature DB >> 11777629

Irradiation of paranasal sinus tumors, a delineation and dose comparison study.

Coen Rasch1, Avraham Eisbruch, Peter Remeijer, Luc Bos, Mischa Hoogeman, Marcel van Herk, Joos V Lebesque.   

Abstract

PURPOSE: To determine the influence of observer variation and treatment planner variation on the dose delivered to the target and normal structures when irradiating paranasal sinus carcinomas. PATIENTS AND METHODS: Nine patients with paranasal sinus tumors underwent debulking surgery and subsequent radiation therapy. Two observers from two different institutions delineated the clinical target volumes (CTVs) for the elective and the boost volumes. These volumes were expanded in three dimensions with a 5-mm margin. At both institutions, a three-dimensional conformal treatment plan of 46 Gy to the elective volumes, plus 20 Gy to the boost target volumes, was designed. The delineated volumes and treatment plans were compared.
RESULTS: The mean volume ratio between institutions of the elective CTVs was 0.9 (standard error = 0.05). The differences were located mainly at the bottom of the nasal cavity and at the frontal border of the target areas. The differences in boost CTVs were large; the mean volume ratio was 2.6 (standard error = 0.58). After expansion of the CTV, the mean distance between the planning target volume (PTV) and the chiasm differed by 0.5 cm between the two institutions. Cases with smaller distances between the PTV and the chiasm had more underdosage to the PTV. This effect was less pronounced for institution A (1 vol.%/cm) than for institution B (10 vol.%/cm) treatment plans, which were less conformal. When the treatment plan was designed for the PTV of institution B, 23 volume % of the PTV of institution A received <95% of the prescribed dose. If the treatment plan was designed for the (on average larger) PTV of institution A, the underdosed volume of PTV at institution B was 17%. The relative underdosage to the "other" PTV was larger when the original treatment plan was more conformal.
CONCLUSION: In the irradiation of paranasal sinus cancer, both the treatment planner and the observer have a significant influence on the dose to the target and organs at risk. Both effects are similar in magnitude. The observer effect increases with more conformal treatment plans. Minimizing the observer variation is important for adequate irradiation of paranasal sinus cancer.

Entities:  

Mesh:

Year:  2002        PMID: 11777629     DOI: 10.1016/s0360-3016(01)01751-5

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  14 in total

1.  A gradient-based method for segmenting FDG-PET images: methodology and validation.

Authors:  Xavier Geets; John A Lee; Anne Bol; Max Lonneux; Vincent Grégoire
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03-13       Impact factor: 9.236

Review 2.  Balancing risk and reward in target delineation for highly conformal radiotherapy in head and neck cancer.

Authors:  Avraham Eisbruch; Vincent Gregoire
Journal:  Semin Radiat Oncol       Date:  2009-01       Impact factor: 5.934

3.  Interobserver variability of clinical target volume delineation in supra-diaphragmatic Hodgkin's disease: a multi-institutional experience.

Authors:  Domenico Genovesi; Giampiero Ausili Cèfaro; Annamaria Vinciguerra; Antonietta Augurio; Monica Di Tommaso; Rita Marchese; Umberto Ricardi; Andrea Riccardo Filippi; Theodore Girinsky; Katiuscia Di Biagio; Maurizio Belfiglio; Enza Barbieri; Vincenzo Valentini
Journal:  Strahlenther Onkol       Date:  2011-05-16       Impact factor: 3.621

4.  Interobserver variation in clinical target volume and organs at risk segmentation in post-parotidectomy radiotherapy: can segmentation protocols help?

Authors:  M Mukesh; R Benson; R Jena; A Hoole; T Roques; C Scrase; C Martin; G A Whitfield; J Gemmill; S Jefferies
Journal:  Br J Radiol       Date:  2012-08       Impact factor: 3.039

Review 5.  Interobserver variation in parotid gland delineation: a study of its impact on intensity-modulated radiotherapy solutions with a systematic review of the literature.

Authors:  S W Loo; W M C Martin; P Smith; S Cherian; T W Roques
Journal:  Br J Radiol       Date:  2012-08       Impact factor: 3.039

6.  Quantifying the dosimetric impact of organ-at-risk delineation variability in head and neck radiation therapy in the context of patient setup uncertainty.

Authors:  Eric Aliotta; Hamidreza Nourzadeh; Jeffrey Siebers
Journal:  Phys Med Biol       Date:  2019-07-05       Impact factor: 3.609

7.  Hierarchical Vertex Regression-Based Segmentation of Head and Neck CT Images for Radiotherapy Planning.

Authors: 
Journal:  IEEE Trans Image Process       Date:  2018-02       Impact factor: 10.856

8.  Decreased 3D observer variation with matched CT-MRI, for target delineation in Nasopharynx cancer.

Authors:  Coen R N Rasch; Roel J H M Steenbakkers; Isabelle Fitton; Joop C Duppen; Peter J C M Nowak; Frank A Pameijer; Avraham Eisbruch; Johannes H A M Kaanders; Frank Paulsen; Marcel van Herk
Journal:  Radiat Oncol       Date:  2010-03-15       Impact factor: 3.481

9.  3D Variation in delineation of head and neck organs at risk.

Authors:  Charlotte L Brouwer; Roel J H M Steenbakkers; Edwin van den Heuvel; Joop C Duppen; Arash Navran; Henk P Bijl; Olga Chouvalova; Fred R Burlage; Harm Meertens; Johannes A Langendijk; Aart A van 't Veld
Journal:  Radiat Oncol       Date:  2012-03-13       Impact factor: 3.481

10.  Interobserver variability in organ at risk delineation in head and neck cancer.

Authors:  J van der Veen; A Gulyban; S Willems; F Maes; S Nuyts
Journal:  Radiat Oncol       Date:  2021-06-28       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.