Literature DB >> 11777399

Characterization and biocompatibility studies of novel humic acids based films as membrane material for an implantable glucose sensor.

I Galeska1, T Hickey, F Moussy, D Kreutzer, F Papadimitrakopoulos.   

Abstract

Multilayered films of humic acids (HAs) (naturally occurring biopolymers) were investigated as a potential semipermeable membrane for implantable glucose sensors. These films were grown using a layer-by-layer self-assembly process of HAs and oppositely charged ferric ions. The growth of these assemblies exhibited strong dependence on the pH and ionic strength of HAs solutions, which correlated with the degree of ionization of the carboxyl groups and neutralization-induced surface spreading. Quartz crystal microbalance (QCM) and ellipsometric studies have shown repeatable, stepwise increase in mass (as high as 5.63 microg/cm(2)) and in film thickness (ca. 24.3 nm per layer) for these assemblies. The permeability of glucose through these membranes can be regulated by varying the number of self-assembled HAs/Fe(3+) layers. Moreover, a 200 nm thick HAs/Fe(3+) film (in its hydrated state) had a shear modulus of about 80 MPa, implying stability upon implantation. These films were determined to be biocompatible since in vivo studies indicated only mild tissue reaction along with some neovascularization.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11777399     DOI: 10.1021/bm010112y

Source DB:  PubMed          Journal:  Biomacromolecules        ISSN: 1525-7797            Impact factor:   6.988


  10 in total

Review 1.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

Review 2.  Single walled carbon nanotubes as reporters for the optical detection of glucose.

Authors:  Paul W Barone; Michael S Strano
Journal:  J Diabetes Sci Technol       Date:  2009-03-01

3.  Layer-by-layer assembled semipermeable membrane for amperometric glucose sensors.

Authors:  Ritesh Tipnis; Santhisagar Vaddiraju; Faquir Jain; Diane J Burgess; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2007-03

4.  Electrospun fibro-porous polyurethane coatings for implantable glucose biosensors.

Authors:  Ning Wang; Krishna Burugapalli; Wenhui Song; Justin Halls; Francis Moussy; Asim Ray; Yudong Zheng
Journal:  Biomaterials       Date:  2012-11-09       Impact factor: 12.479

5.  Controlled release of dexamethasone from PLGA microspheres embedded within polyacid-containing PVA hydrogels.

Authors:  Isabela Galeska; Tae-Kyoung Kim; Siddhesh D Patil; Upkar Bhardwaj; Debjit Chatttopadhyay; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  AAPS J       Date:  2005-09-02       Impact factor: 4.009

6.  Enhanced glucose sensor linearity using poly(vinyl alcohol) hydrogels.

Authors:  Santhisagar Vaddiraju; Hardeep Singh; Diane J Burgess; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

7.  The role of H2O2 outer diffusion on the performance of implantable glucose sensors.

Authors:  S Vaddiraju; D J Burgess; F C Jain; F Papadimitrakopoulos
Journal:  Biosens Bioelectron       Date:  2008-08-19       Impact factor: 10.618

8.  Enhancing the sensitivity of needle-implantable electrochemical glucose sensors via surface rebuilding.

Authors:  Santhisagar Vaddiraju; Allen Legassey; Liangliang Qiang; Yan Wang; Diane J Burgess; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

Review 9.  Emerging synergy between nanotechnology and implantable biosensors: a review.

Authors:  Santhisagar Vaddiraju; Ioannis Tomazos; Diane J Burgess; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  Biosens Bioelectron       Date:  2009-12-11       Impact factor: 10.618

Review 10.  Monitoring with In Vivo Electrochemical Sensors: Navigating the Complexities of Blood and Tissue Reactivity.

Authors:  Pankaj Vadgama
Journal:  Sensors (Basel)       Date:  2020-06-02       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.