Literature DB >> 11775660

High accuracy non-contact ultrasonic thickness gauging of aluminium sheet using electromagnetic acoustic transducers.

S Dixon1, C Edwards, S B Palmer.   

Abstract

Aluminium sheet thickness has been calculated from ultrasonic data obtained using a send-receive, radially polarised electromagnetic acoustic transducer (EMAT). Sheets in the thickness range between 0.1 and 0.5 mm have been measured using this non-contact approach at a stand-off of up to 1.5 mm. Normal incidence shear waves generated and detected in the sheet and the resultant waveforms have been processed using transit time measurements and Fourier analysis. Two broad band EMAT systems have been used to perform the measurements with centre frequencies of approximately 5 MHz and frequency content up to 10 and 20 MHz respectively. The most accurate measurements of thickness on thin sheets have been made using Fourier analysis and have yielded measurements accurate to within 0.2% (or 0.4 microm) for 280 microm thick aluminium sheets. Discrete shear wave echoes can be observed for sheets down to a thickness of 250 microm using the higher frequency EMAT system. However temporal measurements of these signals yield lower accuracy results when compared to the Fourier analysis method which is capable of sub-micron accuracy.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11775660     DOI: 10.1016/s0041-624x(01)00083-x

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  5 in total

1.  Imaging gigahertz zero-group-velocity Lamb waves.

Authors:  Qingnan Xie; Sylvain Mezil; Paul H Otsuka; Motonobu Tomoda; Jérôme Laurent; Osamu Matsuda; Zhonghua Shen; Oliver B Wright
Journal:  Nat Commun       Date:  2019-05-20       Impact factor: 14.919

2.  High-temperature piezoelectric sensing.

Authors:  Xiaoning Jiang; Kyungrim Kim; Shujun Zhang; Joseph Johnson; Giovanni Salazar
Journal:  Sensors (Basel)       Date:  2013-12-20       Impact factor: 3.576

3.  High Temperature Shear Horizontal Electromagnetic Acoustic Transducer for Guided Wave Inspection.

Authors:  Maria Kogia; Tat-Hean Gan; Wamadeva Balachandran; Makis Livadas; Vassilios Kappatos; Istvan Szabo; Abbas Mohimi; Andrew Round
Journal:  Sensors (Basel)       Date:  2016-04-22       Impact factor: 3.576

4.  Experimental Evaluation of Three Designs of Electrodynamic Flexural Transducers.

Authors:  Tobias J R Eriksson; Michael Laws; Lei Kang; Yichao Fan; Sivaram N Ramadas; Steve Dixon
Journal:  Sensors (Basel)       Date:  2016-08-25       Impact factor: 3.576

5.  Terahertz Displacement and Thickness Sensor with Micrometer Resolution and Centimeter Dynamic Range.

Authors:  Dae-Hyun Han; Lae-Hyong Kang
Journal:  Sensors (Basel)       Date:  2019-11-29       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.