Literature DB >> 11774111

Vitamin E-bonded hemodialyzer improves neutrophil function and oxidative stress in patients with end-stage renal failure.

Shuichi Tsuruoka1, Atsuhiro Kawaguchi, Kenta Nishiki, Tokie Hayasaka, Chie Fukushima, Kohichi Sugimoto, Tetsuo Saito, Akio Fujimura.   

Abstract

We evaluated the biocompatibility of a newly developed vitamin E hemodialyzer (CL-EE; Terumo Co Ltd, Tokyo, Japan) by neutrophil function and oxidant stress in patients with end-stage renal failure in a randomized crossover study. Ten patients underwent hemodialysis using either the CL-EE or a control dialyzer membrane identical to the CL-EE except for vitamin E binding for 12 weeks in a crossover fashion after a 1-month washout period with hemophane membranes. White blood cell counts, serum oxidized low-density lipoprotein (Ox-LDL) levels, and malondialdehyde (MDA) levels during hemodialysis sessions were measured at the initiation and end of the CL-EE and control trials. Superoxide anion production by neutrophils just before and 4 hours after starting the session also was measured. Leukocytopenia at 1 hour after starting the session was detected to a similar extent in both membranes. However, the degree of reduction was less in the CL-EE trial after repeated use. Superoxide anion production by neutrophils just before a hemodialysis session was reduced after repeated use of the CL-EE membrane. Serum Ox-LDL levels increased, whereas serum MDA levels decreased during sessions to a similar extent in both trials. However, these parameters were significantly lower in the CL-EE trial after repeated use. Serum LDL concentrations significantly decreased with repeated use of the CL-EE membrane. These data suggest that repeated use of the CL-EE membrane for 3 months improves neutrophil function, oxidant stress, and LDL concentrations in patients with renal failure. This membrane may be useful to reduce the incidence of cardiovascular events in patients with renal failure. Copyright 2002 by the National Kidney Foundation, Inc.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11774111     DOI: 10.1053/ajkd.2002.29901

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  5 in total

1.  Development of vitamin E-modified polysulfone membrane dialyzers.

Authors:  Masatomi Sasaki
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

Review 2.  Cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease.

Authors:  A M Macleod; M Campbell; J D Cody; C Daly; C Donaldson; A Grant; I Khan; K S Rabindranath; L Vale; S Wallace
Journal:  Cochrane Database Syst Rev       Date:  2005-07-20

Review 3.  Oxidative Stress in Hemodialysis Patients: A Review of the Literature.

Authors:  Vassilios Liakopoulos; Stefanos Roumeliotis; Xenia Gorny; Evangelia Dounousi; Peter R Mertens
Journal:  Oxid Med Cell Longev       Date:  2017-09-12       Impact factor: 6.543

4.  Vitamin E-Bonded Membranes Do Not Influence Markers of Oxidative Stress in Hemodialysis Patients with Homozygous Glutathione Transferase M1 Gene Deletion.

Authors:  Petar Djuric; Sonja Suvakov; Tatjana Simic; Dragana Markovic; Djurdja Jerotic; Aleksandar Jankovic; Ana Bulatovic; Jelena Tosic Dragovic; Tatjana Damjanovic; Jelena Marinkovic; Radomir Naumovic; Nada Dimkovic
Journal:  Toxins (Basel)       Date:  2020-05-27       Impact factor: 4.546

Review 5.  Antiatherogenic effects of vitamin E: the search for the Holy Grail.

Authors:  Dimitrios Kirmizis; Dimitrios Chatzidimitriou
Journal:  Vasc Health Risk Manag       Date:  2009-09-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.