Literature DB >> 11772669

Tissue harmonic imaging improves organ visualization in trauma ultrasound when compared with standard ultrasound mode.

Michael Blaivas1, Daniel DeBehnke, Paul R Sierzenski, Mary Beth Phelan.   

Abstract

UNLABELLED: The focused abdominal sonography for trauma (FAST) examination is complicated by brightly lit trauma bays, limited time, and body habitus. Recently, new ultrasound (US) technology has become available that improves organ visualization in abdominal scans.
OBJECTIVE: The hypothesis was that a new US mode, tissue harmonic (TH) imaging, improves visualization of critical organ relationships in the FAST examination by making use of previously unused frequencies. The authors performed a blind, prospective observational study to compare the images obtained in typical FAST views with those obtained in standard US and TH modes.
METHODS: Blunt trauma patients presenting to a level I trauma center between April and September 2000 were enrolled on a convenience basis. Typical FAST views were obtained in standard and TH modes. The emergency ultrasonographer (EU) switched between modes for each view, optimizing the gain each time. Multiple digital still images were made with all indications of the mode used disguised. For each view on a patient, the best image in each mode was selected in a blinded fashion. Three experienced EUs, blinded to the mode used, rated each image pair for resolution, detail, and total image quality as previously defined on a ten-point Likert scale, 10 being the best for each category. Wilcoxon signed-ranks test, 95% confidence intervals (95% CIs), and interobserver correlation were calculated.
RESULTS: A total of 76 image groups (39 of Morison's pouch, 20 splenorenal, and 17 bladder) from 52 patients were rated. Tissue harmonics produced improved resolution, detail, and quality when compared with the standard US mode, with median scores of 6.7 vs. 6.0, 6.7 vs. 6.0, and 6.3 vs. 6.0, respectively. The differences of 0.7 (95% CI = 0.4 to 0.93), 0.7 (95% CI = 0.4 to 0.93), and 0.33 (95% CI = 0.17 to 0.67) were statistically significant, with p = 0.0001, 0.0001, and 0.0003, respectively. There was good interobserver agreement (kappa = 0.74; 95% CI = 0.68 to 0.79).
CONCLUSIONS: Tissue harmonics produced FAST images higher in detail, resolution, and total image quality than standard-mode US images.

Entities:  

Mesh:

Year:  2002        PMID: 11772669     DOI: 10.1111/j.1553-2712.2002.tb01166.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  4 in total

1.  Harmonic versus conventional ultrasound imaging of the urinary tract in children.

Authors:  Ulrike Bartram; Kassa Darge
Journal:  Pediatr Radiol       Date:  2005-03-05

2.  Comparing the image quality of tissue harmonic and conventional B-mode ultrasound of kidney in over-obese individuals.

Authors:  Hossein Rezaei-Dalouei; Farrokh Seilanian-Toosi; Sirous Nekooei; Behrouz Davachi; Azita Azarian; Bita Abbasi
Journal:  Electron Physician       Date:  2018-07-25

3.  Development and evaluation of a novel, real time mobile telesonography system in management of patients with abdominal trauma: study protocol.

Authors:  Chinwe Ogedegbe; Herman Morchel; Vikki Hazelwood; William F Chaplin; Joseph Feldman
Journal:  BMC Emerg Med       Date:  2012-12-18

4.  Performance of novel tissue harmonic echo imaging using endoscopic ultrasound for pancreatic diseases.

Authors:  Kazuyuki Matsumoto; Akio Katanuma; Hiroyuki Maguchi; Kuniyuki Takahashi; Manabu Osanai; Kei Yane; Toshifumi Kin; Ryo Takaki; Tomoaki Matsumori; Katsushige Gon; Akiko Tomonari; Masanori Nojima
Journal:  Endosc Int Open       Date:  2015-11-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.