Monte Carlo simulation of a dynamic MLC based on a multiple source model.

M K Fix1, P Manser, E J Born, R Mini, P Rüegsegger.   

Abstract

Detailed knowledge of the characteristics of the radiation field shaped by a multileaf collimator (MLC) is essential in intensity modulated radiotherapy (IMRT). A previously developed multiple source model (MSM) for a 6 MV beam was extended to a 15 MV beam and supplemented with an accurate model of an 80-leaf dynamic MLC. Using the supplemented MSM and the MC code GEANT, lateral dose distributions were calculated in a water phantom and a portal water phantom. A field which is normally used for the validation of the step and shoot technique and a field from a realistic IMRT treatment plan delivered with dynamic MLC are investigated. To assess possible spectral changes caused by the modulation of beam intensity by an MLC, the energy spectra in five portal planes were calculated for moving slits of different widths. The extension of the MSM to 15 MV was validated by analysing energy fluences, depth doses and dose profiles. In addition, the MC-calculated primary energy spectrum was verified with an energy spectrum which was reconstructed from transmission measurements. MC-calculated dose profiles using the MSM for the step and shoot case and for the dynamic MLC case are in very good agreement with the measured data from film dosimetry. The investigation of a 13 cm wide field shows an increase in mean photon energy of up to 16% for the 0.25 cm slit compared to the open beam for 6 MV and of up to 6% for 15 MV, respectively. In conclusion, the MSM supplemented with the dynamic MLC has proven to be a powerful tool for investigational and benchmarking purposes or even for dose calculations in IMRT.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11768503     DOI: 10.1088/0031-9155/46/12/312

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.

Authors:  I B Mihaylov; F A Lerma; Y Wu; J V Siebers
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

2.  Calculated organ doses from selected prostate treatment plans using Monte Carlo simulations and an anatomically realistic computational phantom.

Authors:  Bryan Bednarz; Cindy Hancox; X George Xu
Journal:  Phys Med Biol       Date:  2009-08-11       Impact factor: 3.609

3.  Moving GPU-OpenCL-based Monte Carlo dose calculation toward clinical use: Automatic beam commissioning and source sampling for treatment plan dose calculation.

Authors:  Zhen Tian; Yongbao Li; Nima Hassan-Rezaeian; Steve B Jiang; Xun Jia
Journal:  J Appl Clin Med Phys       Date:  2017-02-16       Impact factor: 2.102

4.  Monte Carlo Investigation of Photon Beam Characteristics and its Variation with Incident Electron Beam Parameters for Indigenous Medical Linear Accelerator.

Authors:  Subhalaxmi Mishra; P K Dixit; T Palani Selvam; Sanket S Yavalkar; D D Deshpande
Journal:  J Med Phys       Date:  2018 Jan-Mar
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.