Literature DB >> 11768502

Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery.

M Alber1, F Nüsslin.   

Abstract

Multi-leaf collimators (MLCs) are emerging as the prevalent modality to apply intensity modulated radiotherapy (IMRT). Both the principle and the particular design of MLCs stipulate complex constraints on the practically applicable intensity modulated radiation fields. Most consequentially, the distribution of exposure times across the maximum field outline is either a piecewise constant function in the static mode or a piecewise linear function in the dynamic mode of driving an MLC. In view of clinical utility, the total leaf movement should be minimized, which requires that MLC-related constraints be considered in the dose optimization process. A method is proposed to achieve this for both static MLC fields and dynamic leaf close-in application. The method is an amendment to a generic gradient-based IMRT dose optimization algorithm and solves numerical problems related to the non-convexity of the MLC constraints, which can cause erratic behaviour of a gradient-based algorithm. It employs bistable penalty functions to select preferrable leaf configurations from the configuration space of the MLC, which is limited by specific design features. Together with an 'annealing' escape mechanism from local minima, the algorithm is capable of finding the optimum of an IMRT problem as leaf sequences with minimized leaf travel. In particular, the efficiency of static IMRT can be raised to the levels of unmodulated fields with very few field segments, thereby increasing the utility of IMRT in clinical practice.

Entities:  

Mesh:

Year:  2001        PMID: 11768502     DOI: 10.1088/0031-9155/46/12/311

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Balancing control and simplicity: A variable aggregation method in intensity modulated radiation therapy planning.

Authors:  Philipp Süss; Karl-Heinz Küfer
Journal:  Linear Algebra Appl       Date:  2008-03-01       Impact factor: 1.401

2.  [Development of methods and instruments for radiation therapy. The most important developments from the viewpoint of a physicist].

Authors:  P Kneschaurek; F Nüsslin
Journal:  Strahlenther Onkol       Date:  2012-11       Impact factor: 3.621

3.  Trimmer sequencing time minimization during dynamically collimated proton therapy using a colony of cooperating agents.

Authors:  Blake R Smith; Daniel E Hyer; Ryan T Flynn; Patrick M Hill; Wesley S Culberson
Journal:  Phys Med Biol       Date:  2019-10-21       Impact factor: 3.609

4.  Pre-segmented 2-Step IMRT with subsequent direct machine parameter optimisation - a planning study.

Authors:  Klaus Bratengeier; Jürgen Meyer; Michael Flentje
Journal:  Radiat Oncol       Date:  2008-11-06       Impact factor: 3.481

5.  IMRT of prostate cancer: a comparison of fluence optimization with sequential segmentation and direct step-and-shoot optimization.

Authors:  Marius Treutwein; Matthias Hipp; Oliver Kölbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2009-06-09       Impact factor: 3.621

6.  On the performances of different IMRT Treatment Planning Systems for selected paediatric cases.

Authors:  Antonella Fogliata; Giorgia Nicolini; Markus Alber; Mats Asell; Alessandro Clivio; Barbara Dobler; Malin Larsson; Frank Lohr; Friedlieb Lorenz; Jan Muzik; Martin Polednik; Eugenio Vanetti; Dirk Wolff; Rolf Wyttenbach; Luca Cozzi
Journal:  Radiat Oncol       Date:  2007-02-15       Impact factor: 3.481

7.  Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node SPECT imaging for target volume definition.

Authors:  Ute Ganswindt; Frank Paulsen; Stefan Corvin; Kai Eichhorn; Stefan Glocker; Ilse Hundt; Mattias Birkner; Markus Alber; Aristotelis Anastasiadis; Arnulf Stenzl; Roland Bares; Wilfried Budach; Michael Bamberg; Claus Belka
Journal:  BMC Cancer       Date:  2005-07-28       Impact factor: 4.430

8.  Monte Carlo vs. pencil beam based optimization of stereotactic lung IMRT.

Authors:  Marcin Sikora; Jan Muzik; Matthias Söhn; Martin Weinmann; Markus Alber
Journal:  Radiat Oncol       Date:  2009-12-12       Impact factor: 3.481

9.  Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma.

Authors:  Barbara Dobler; Fabian Pohl; Ludwig Bogner; Oliver Koelbl
Journal:  Radiat Oncol       Date:  2007-09-06       Impact factor: 3.481

10.  An Automated Treatment Plan Quality Control Tool for Intensity-Modulated Radiation Therapy Using a Voxel-Weighting Factor-Based Re-Optimization Algorithm.

Authors:  Ting Song; Nan Li; Masoud Zarepisheh; Yongbao Li; Quentin Gautier; Linghong Zhou; Loren Mell; Steve Jiang; Laura Cerviño
Journal:  PLoS One       Date:  2016-03-01       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.