Literature DB >> 11768459

A new calcium-sensor based on ion-selective conductometric microsensors--membranes and features.

U Trebbe1, M Niggemann, K Cammann, G C Fiaccabrino, M Koudelka-Hep, S Dzyadevich, O Shulga.   

Abstract

Based on the concept of ion-selective conductometric microsensors (ISCOM) a new calcium sensor was developed and characterized. ISCOM have a single probe, all-solid-state construction and do not need a reference electrode. These sensors are amenable to miniaturization and integration in the true sense of integrated circuit and microsystem technologies. The detection is accomplished by measurement of the bulk conductance Gm of a thin polymeric membrane containing an ion-complexing agent, where the magnitude of Gm can be related to the content of the primary ion in the analyzed solution. Thin-film platinum electrodes forming an interdigitated electrode are used as the transducer to detect the conductivity of the polymeric membrane. Optimization of the membrane composition was carried out by testing different types of calcium-ionophores, polymers, and plasticizers. The sensor characteristics have been investigated. The limit of detection is about 10(-7) mol L(-1). The dynamic range is 10(-6)-10(-1) mol L(-1) with a response time of less than 5 s. These parameters are comparable to those of corresponding potentiometric calcium selective electrodes (ISE). The Ca(2+)-ISCOM demonstrates good practical relevant selectivities against typical interfering ions for biomedical and environmental applications.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11768459     DOI: 10.1007/s002160101093

Source DB:  PubMed          Journal:  Fresenius J Anal Chem        ISSN: 0937-0633


  3 in total

1.  Selective detection of live pathogens via surface-confined electric field perturbation on interdigitated silicon transducers.

Authors:  Roberto de la Rica; Antonio Baldi; César Fernández-Sánchez; Hiroshi Matsui
Journal:  Anal Chem       Date:  2009-05-15       Impact factor: 6.986

Review 2.  Conductometric Microbiosensors for Environmental Monitoring.

Authors:  Nicole Jaffrezic-Renault; Sergei V Dzyadevych
Journal:  Sensors (Basel)       Date:  2008-04-11       Impact factor: 3.576

3.  Towards fully integrated wireless impedimetric sensors.

Authors:  Fredy Segura-Quijano; Jordi Sacristán-Riquelme; Jesús García-Cantón; Maria Teresa Osés; Antonio Baldi
Journal:  Sensors (Basel)       Date:  2010-04-21       Impact factor: 3.576