STUDY
OBJECTIVES: Because sleep and wakefulness differ from each other by the amount of body movement, it has been claimed that the two states can be accurately distinguished by wrist actigraphy. Our objective was to test this claim in lengthy polysomnographic (psg) and actigraphic (acf) samples that included night and day components.
DESIGN: Fourteen healthy young (21-35 years) and old (70-72 years) men and women lived in a laboratory without temporal cues for 7 days. Each subject continuously wore sleep-recording electrodes as well as 2 wrist-movement recorders. Act measurements were converted to predictions of sleep and wakefulness by simple-threshold and multiple-regression methods. Psg served as the gold standard for calculation of predictive values (PV, the probability that an act prediction is correct by psg criteria).
SETTING: N/A. PARTICIPANTS: N/A.
INTERVENTIONS: N/A. MEASUREMENTS AND
RESULTS: The 7-day act recordings showed clear circadian cycles of high and low activity that respectively corresponded to subjective days, when subjects were wakeful, and subjective nights when they slept. Lower act levels corresponded to deeper states of psg sleep. Logistic regression on a 20-minute moving average of act gave the highest overall PV's. Nevertheless, the mean PV for sleep (PVS) was only 62.2% in complete, day + night samples. PVS was 86.6% in night samples. Act successfully predicted wakefulness during subjective nights (PVW = 89.6) and accurately measured circadian period length and the extent of sleep-wake consolidation, but it overestimated sleep rate and sleep efficiency. Act systematically decreased before sleep onset and increased before awakening, but reliable transitions among joint psg/act states (the Markov-1 property) were not demonstrated.
CONCLUSIONS: Low PV's and overestimation of sleep currently disqualify actigraphy as an accurate sleep-wake indicator. Actigraphy may, however, by useful for measuring circadian period and sleep-wake consolidation and has face validity as a measure of rest/activity.

Entities:  

Mesh:

Year:  2001        PMID: 11766166     DOI: 10.1093/sleep/24.8.957

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  54 in total

1.  Circadian activity rhythms and risk of incident dementia and mild cognitive impairment in older women.

Authors:  Gregory J Tranah; Terri Blackwell; Katie L Stone; Sonia Ancoli-Israel; Misti L Paudel; Kristine E Ensrud; Jane A Cauley; Susan Redline; Teresa A Hillier; Steven R Cummings; Kristine Yaffe
Journal:  Ann Neurol       Date:  2011-11       Impact factor: 10.422

2.  Validity of activity-based devices to estimate sleep.

Authors:  Allison R Weiss; Nathan L Johnson; Nathan A Berger; Susan Redline
Journal:  J Clin Sleep Med       Date:  2010-08-15       Impact factor: 4.062

3.  Maximum daily 6 minutes of activity: an index of functional capacity derived from actigraphy and its application to older adults with heart failure.

Authors:  Jason Howell; B Michelle Strong; Jenny Weisenberg; Anagha Kakade; Qian Gao; Paul Cuddihy; Susan Delisle; Stan Kachnowski; Mathew S Maurer
Journal:  J Am Geriatr Soc       Date:  2010-03-30       Impact factor: 5.562

4.  Performance of a Portable Sleep Monitoring Device in Individuals with High Versus Low Sleep Efficiency.

Authors:  Rachel R Markwald; Sara C Bessman; Seth A Reini; Sean P A Drummond
Journal:  J Clin Sleep Med       Date:  2016-01       Impact factor: 4.062

5.  Activity in the chronically critically ill.

Authors:  Chris Winkelman; Patricia A Higgins; Yea-Jyh Kathy Chen
Journal:  Dimens Crit Care Nurs       Date:  2005 Nov-Dec

6.  Associations between circadian activity rhythms and functional brain abnormalities among euthymic bipolar patients: a preliminary study.

Authors:  Benjamin S McKenna; Sean P A Drummond; Lisa T Eyler
Journal:  J Affect Disord       Date:  2014-04-21       Impact factor: 4.839

7.  Heart rate-based nighttime awakening detection.

Authors:  Arnoud Bulckaert; Vasileios Exadaktylos; Guido De Bruyne; Bart Haex; Elke De Valck; Johan Wuyts; Johan Verbraecken; Daniel Berckmans
Journal:  Eur J Appl Physiol       Date:  2010-01-23       Impact factor: 3.078

8.  Agreement between actigraphic and polysomnographic measures of sleep in adults with and without chronic conditions: A systematic review and meta-analysis.

Authors:  Samantha Conley; Andrea Knies; Janene Batten; Garrett Ash; Brienne Miner; Youri Hwang; Sangchoon Jeon; Nancy S Redeker
Journal:  Sleep Med Rev       Date:  2019-05-13       Impact factor: 11.609

Review 9.  Use of actigraphy for assessment in pediatric sleep research.

Authors:  Lisa J Meltzer; Hawley E Montgomery-Downs; Salvatore P Insana; Colleen M Walsh
Journal:  Sleep Med Rev       Date:  2012-03-15       Impact factor: 11.609

10.  Concordance of polysomnographic and actigraphic measurement of sleep and wake in older women with insomnia.

Authors:  Diana M Taibi; Carol A Landis; Michael V Vitiello
Journal:  J Clin Sleep Med       Date:  2013-03-15       Impact factor: 4.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.