Literature DB >> 11764904

Internal current mark in a case of suicide by electrocution.

S Anders1, J Matschke, M Tsokos.   

Abstract

Fatalities caused by electrocution often lack specific morphologic evidence. Investigation of the death scene along with technical inspection of the electrical apparatus may help in clarifying the cause and manner of death. Cutaneous current marks may be the only sign of low voltage associated fatalities. The authors report a case of an electrician who committed suicide by electrocution using a time switch after oral ingestion of diazepam. Electrodes (coins) were fixed with adhesive tape at the height of the heart to the front and back of the left side of the chest. Autopsy revealed a blackish linear mark on the pleura parietalis of the inner side of the thoracic cavity, connecting the cutaneous current marks. Current-related and heat-related changes, such as hypercontraction bands of the intercostal muscles and coagulative changes of the perineurium of peripheral nerves, were found at histologic examination. Taking into consideration that the body had been under the influence of low-voltage current for 7 days, the morphologic alteration on the pleura parietalis was in accordance with an internal current mark, indicating the main route of current flow through the body. To the authors' knowledge, such a current-related phenomenon has not been reported to occur on an inner body surface before.

Entities:  

Mesh:

Year:  2001        PMID: 11764904     DOI: 10.1097/00000433-200112000-00007

Source DB:  PubMed          Journal:  Am J Forensic Med Pathol        ISSN: 0195-7910            Impact factor:   0.921


  4 in total

1.  Electric fences and accidental death.

Authors:  Michael Burke; Morris Odell; Heinrich Bouwer; Adam Murdoch
Journal:  Forensic Sci Med Pathol       Date:  2017-03-28       Impact factor: 2.007

2.  Anterior wrist and medial malleolus as the novel sites of tissue selection: a retrospective study on electric shock death through the hand-to-foot circuit pathway.

Authors:  Guangtao Xu; Ruibing Su; Junyao Lv; Bo Hu; Huan Gu; Xianxian Li; Jiang Gu; Xiaojun Yu
Journal:  Int J Legal Med       Date:  2017-01-06       Impact factor: 2.686

3.  Just another railway fatality.

Authors:  Vanessa Preuss; Benedikt Vennemann; Michael Klintschar
Journal:  Int J Legal Med       Date:  2020-01-15       Impact factor: 2.686

4.  Identification of Skin Electrical Injury Using Infrared Imaging: A Possible Complementary Tool for Histological Examination.

Authors:  Ji Zhang; Wei Lin; Hancheng Lin; Zhenyuan Wang; Hongmei Dong
Journal:  PLoS One       Date:  2017-01-24       Impact factor: 3.240

  4 in total