Literature DB >> 11764858

UV radiation emitted by selected sources at work stands.

C Kozłowski1.   

Abstract

The paper presents the results of UV effective irradiance measurements at work stands for sources such as: welding arcs, gas blowpipes, exposure processes, printing machines and insecticide lamps. The irradiance measurements were performed using broad-band instruments with detector heads corrected to the Polish action spectra (erythematous and conjunctivitis). The obtained values of effective irradiance for the above sources ranged from 0.2 to 8,000 mW/m2. Safe exposure time corresponding to irradiance was calculated for the Polish threshold limit values. For welding processes the spectra of selected welding arcs are presented additionally. These spectra were measured using a fiber-optic spectrometer.

Entities:  

Mesh:

Year:  2001        PMID: 11764858

Source DB:  PubMed          Journal:  Int J Occup Med Environ Health        ISSN: 1232-1087            Impact factor:   1.843


  2 in total

1.  Pattern of eye diseases among welders in a Nigeria community.

Authors:  A Ajayi Iyiade; J Omotoye Olusola
Journal:  Afr Health Sci       Date:  2012-06       Impact factor: 0.927

2.  Early and late spectral domain optical coherence tomography features of acute welding maculopathy.

Authors:  Mohammad Hossein Jabbarpoor Bonyadi
Journal:  J Ophthalmic Vis Res       Date:  2013-10
  2 in total