Literature DB >> 11764369

The John Charnley Award: Three-dimensional analysis of the cement mantle in total hip arthroplasty.

G G Valdivia1, M J Dunbar, D A Parker, M R Woolfrey, S J MacDonald, R W McCalden, C H Rorabeck, R B Bourne.   

Abstract

Cemented fixation of the femoral stem is the gold standard for patients older than 60 years. The importance of reliably achieving an adequate cement mantle has been shown in many studies. Currently, inspection and grading of plain radiographs is the accepted method for study of the cement mantle. However, the reliability of plain radiographs for this purpose has been questioned. In addition, the interobserver agreement of current grading systems has been shown to be limited. A new in vitro method of cement mantle analysis is described. Plastic replicas of six contemporary stems were implanted into femurs from cadavers. The specimens were imaged with a computed tomography scanner. Detailed, computer-assisted analysis of mantle thickness was done. Comparisons were made between designs. A subset was compared with standard radiographs. Plain radiographs overestimated thickness and underestimated the deficiencies. There was significant variability in the mantle produced by the different designs. Commonly used designs had deficiencies in their mantles by standard criteria despite proper surgical technique. The importance of being fully acquainted with the particular implant one uses is emphasized by these results. This is a valuable technique for investigation of the effects on the cement mantle of implant design, surgical technique, and patient anatomy.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11764369     DOI: 10.1097/00003086-200112000-00005

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  2008 Otto Aufranc Award: component design and technique affect cement penetration in hip resurfacing.

Authors:  Paul E Beaulé; Wadih Y Matar; Philippe Poitras; Kevin Smit; Olivier May
Journal:  Clin Orthop Relat Res       Date:  2008-10-16       Impact factor: 4.176

2.  Hybrid total hip arthroplasty using specifically-designed stems for patients with developmental dysplasia of the hip. A minimum five-year follow-up study.

Authors:  Hiroshi Ito; Hiromasa Tanino; Yasuhiro Yamanaka; Toshiki Nakamura; Takeo Matsuno
Journal:  Int Orthop       Date:  2010-07-24       Impact factor: 3.075

3.  Quality of the femoral cement mantle in total hip arthroplasty using the direct anterior hip approach.

Authors:  Eustathios Kenanidis; Rajiv Kaila; Lazaros Poultsides; Eleftherios Tsiridis; Panayiotis Christofilopoulos
Journal:  Arthroplast Today       Date:  2020-06-22

4.  The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design.

Authors:  Gavin J Macpherson; Christian Hank; Michael Schneider; Morag Trayner; Robert Elton; Colin R Howie; Steffen J Breusch
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

5.  Fixation of the cemented stem: clinical relevance of the porosity and thickness of the cement mantle.

Authors:  Philippe Hernigou; Gildasio Daltro; Charles Henri Flouzat Lachaniette; Xavier Roussignol; Martin Mukisi Mukasa; Alexandre Poignard
Journal:  Open Orthop J       Date:  2009-02-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.