Literature DB >> 11764340

Total hip arthroplasty using two different cementless tapered stems.

J J Purtill1, R H Rothman, W J Hozack, P F Sharkey.   

Abstract

The authors report their 15-year experience with primary total hip arthroplasty using collarless, tapered, porous-coated femoral stems (Trilock and Taperloc) in patients with osteoarthritis, rheumatoid arthritis, and in octogenarians. Excellent clinical results were achieved in all groups at latest followup. For the patients with Trilock stems, Taperloc stems, and patients who were octogenarians and patients with rheumatoid arthritis, Charnley pain scores were 5.6, 5.5, 5.7, and 5.7; Charnley function scores were 5.2, 5.1, 4.2, and 5.3; Harris hip scores were 92, 92, 82, and 93 points, respectively. There was a 2% rate of thigh pain with the Trilock, 4% with Taperloc, 4% in octogenarians, and 2% in patients with rheumatoid arthritis. In 96% of the patients in the Trilock group, in 100% of the patients in the Taperloc group, in 100% of the patients who were octogenarians, and in 100% of the patients with rheumatoid arthritis, femoral components showed radiographic evidence of bone ingrowth. There were six (12%) femoral component revisions in the Trilock group (all secondary to nonmodularity of the component at the time of acetabular revision), one femoral component revision in the Taperloc group and no femoral component revisions in the patients who were octogenarians or who had rheumatoid arthritis. Design features (collarless tapered wedge fit, circumferentially porous-coated) virtually ensure bone ingrowth and are thought to be responsible for the excellent clinical results and longevity.

Entities:  

Mesh:

Year:  2001        PMID: 11764340     DOI: 10.1097/00003086-200112000-00014

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  11 in total

1.  Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components.

Authors:  Adolph V Lombardi; Keith R Berend; Thomas H Mallory; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

2.  What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17-year followup of a randomized controlled trial.

Authors:  Kristoff Corten; Robert B Bourne; Kory D Charron; Keegan Au; Cecil H Rorabeck
Journal:  Clin Orthop Relat Res       Date:  2010-07-13       Impact factor: 4.176

3.  The correlation between clinical radiological outcome and contact state of implant and femur using three-dimensional templating software in cementless total hip arthroplasty.

Authors:  Daisuke Inoue; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-06-22

4.  Bipolar hemiarthroplasty for femoral neck fracture using the direct anterior approach.

Authors:  Tomonori Baba; Katsuo Shitoto; Kazuo Kaneko
Journal:  World J Orthop       Date:  2013-04-18

5.  Mid-term results using a cementless hip prosthesis in young Chinese patients: a five- to seven-year follow-up study.

Authors:  XueYong Qiu; Jing Yang; Bin Shen; ZongKe Zhou; Hui Zhang; FuXing Pei
Journal:  Int Orthop       Date:  2008-12-03       Impact factor: 3.075

6.  Progressive subsidence of a tapered, proximally coated femoral stem in total hip arthroplasty.

Authors:  Cale A Jacobs; Christian P Christensen
Journal:  Int Orthop       Date:  2008-05-28       Impact factor: 3.075

7.  Seven-year results of a tapered, titanium, hydroxyapatite-coated cementless femoral stem in primary total hip arthroplasty.

Authors:  Jin-Ho Cho; Jonathan P Garino; Suk-Kyu Choo; Kye-Young Han; Jung-Hoon Kim; Hyoung-Keun Oh
Journal:  Clin Orthop Surg       Date:  2010-11-05

8.  10 years results of an uncemented metaphyseal fit modular stem in elderly patients.

Authors:  Basilio J De la Torre; Manuel Chaparro; Juan O Romanillos; Sara Zarzoso; Margarita Mosquera; Gil Rodriguez
Journal:  Indian J Orthop       Date:  2011-07       Impact factor: 1.251

Review 9.  Outcome of the cementless Taperloc stem: a comprehensive literature review including arthroplasty register data.

Authors:  Gerold Labek; Stefan Frischhut; Rainer Schlichtherle; Alexandra Williams; Martin Thaler
Journal:  Acta Orthop       Date:  2011-04       Impact factor: 3.717

Review 10.  Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

Authors:  Paul van der Voort; Bart G Pijls; Marc J Nieuwenhuijse; Jorrit Jasper; Marta Fiocco; Josepha W M Plevier; Saskia Middeldorp; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2015       Impact factor: 3.717

View more