Insertion of an intrauterine contraceptive device after induced or spontaneous abortion: a review of the evidence.

N L Stanwood1, D A Grimes, K F Schulz.   

Abstract

OBJECTIVE: Assess the safety and efficacy of intrauterine contraceptive device (IUCD) insertion immediately after induced or spontaneous abortion.
DESIGN: Systematic search for randomised trials that had at least one treatment arm that involved IUCD insertion immediately after an induced or spontaneous miscarriage using Medline, Popline, EMBASE, and review articles supplemented by correspondence with investigators. POPULATION: Women of any age or gravidity who had an IUCD inserted immediately after evacuation for spontaneous or induced abortion.
METHODS: Articles were abstracted and the raw data from tables were analysed with RevMan 3.1 software. We focused on Tietze-Potter gross life table probabilities with denominators of person-time of exposure. MAIN OUTCOME MEASURES: Rates of perforation, expulsion, pelvic inflammatory disease, contraceptive failure, and method continuation.
RESULTS: Complication rates for immediate post-abortal IUCD insertion were low. Perforation was rare with a rate of approximately one per 1,000 insertions. One year gross cumulative expulsion rates ranged from 1.8% to 12.6%, pregnancy rates from 0.6% to 2.1%, and continuation rates from 54% to 90%. The net discontinuation rate due to pelvic inflammatory disease was low, ranging from 0.0 to 0.8 per 100 women at one year. Increasing gestational age at insertion was associated with increased expulsion rates.
CONCLUSIONS: Post-abortal IUCD insertion is safe and effective. The risks of perforation, expulsion, pelvic inflammatory disease and contraceptive failure were low and similar to those reported for interval insertion. Second trimester gestational age is associated with an increased risk of expulsion. Immediate insertion may have a higher expulsion rate than delayed insertion. However, these risks may be outweighed by the benefit of immediate contraception.

Entities:  

Mesh:

Year:  2001        PMID: 11762657     DOI: 10.1111/j.1471-0528.2003.00264.x

Source DB:  PubMed          Journal:  BJOG        ISSN: 1470-0328            Impact factor:   6.531


  5 in total

1.  Immediate postabortion intrauterine device insertion: continuation and satisfaction.

Authors:  Colleen McNicholas; Taylor Hotchkiss; Tessa Madden; Qiuhong Zhao; Jenifer Allsworth; Jeffrey F Peipert
Journal:  Womens Health Issues       Date:  2012 Jul-Aug

2.  Immediate vs. delayed insertion of intrauterine contraception after second trimester abortion: study protocol for a randomized controlled trial.

Authors:  Wendy V Norman; Janusz Kaczorowski; Judith A Soon; Rollin Brant; Stirling Bryan; Konia J Trouton; Lyda Dicus
Journal:  Trials       Date:  2011-06-14       Impact factor: 2.279

3.  Comparing the effectiveness of copper intrauterine devices available in Canada. Is FlexiT non-inferior to NovaT when inserted immediately after first-trimester abortion? Study protocol for a randomized controlled trial.

Authors:  Wendy V Norman; Jessica L Chiles; Caroline A Turner; Rollin Brant; Andra Aslan; Janusz Kaczorowski
Journal:  Trials       Date:  2012-08-24       Impact factor: 2.279

Review 4.  Postabortion Care: 20 Years of Strong Evidence on Emergency Treatment, Family Planning, and Other Programming Components.

Authors:  Douglas Huber; Carolyn Curtis; Laili Irani; Sara Pappa; Lauren Arrington
Journal:  Glob Health Sci Pract       Date:  2016-09-29

Review 5.  Intrauterine devices and risk of uterine perforation: current perspectives.

Authors:  Sam Rowlands; Emeka Oloto; David H Horwell
Journal:  Open Access J Contracept       Date:  2016-03-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.