Literature DB >> 11761170

Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition.

Young-Taeg Sul1, Carina B Johansson, Sarunas Petronis, Anatol Krozer, Yongsoo Jeong, Ann Wennerberg, Tomas Albrektsson.   

Abstract

Titanium implants have been used widely and successfully for various types of bone-anchored reconstructions. It is believed that properties of oxide films covering titanium implant surfaces are of crucial importance for a successful osseointegration, in particular at compromized bone sites. The aim of the present study is to investigate the surface properties of anodic oxides formed on commercially pure (c.p.) titanium screw implants as well as to study 'native' oxides on turned c.p. titanium implants. Anodic oxides were prepared by galvanostatic mode in CH3COOH up to the high forming voltage of dielectric breakdown and spark formation. The oxide thicknesses, measured with Auger electron spectroscopy (AES), were in the range of about 200-1000 nm. Barrier and porous structures dominated the surface morphology of the anodic film. Quantitative morphometric analyses of the micropore structures were performed using an image analysis system on scanning electron microscopy (SEM) negatives. The pore sizes were < or = 8 microm in diameter and had 1.27-2.1 microm2 opening area. The porosity was in the range of 12.7-24.4%. The surface roughness was in the range of 0.96-1.03 microm (Sa), measured with TopScan 3D. The crystal structures of the titanium oxide were amorphous, anatase, and a mixtures of anatase and rutile type, as analyzed with thin-film X-ray diffractometry (TF-XRD) and Raman spectroscopy. The chemical compositions consisted mainly of TiO2, characterized with X-ray photoelectron spectroscopy (XPS). The native (thermal) oxide on turned implants was 17.4 nm (+/- 6.2) thick and amorphous. Its chemical composition was TiO2. The surface roughness had an average height deviation of 0.83 microm (Sa). The present results are needed to elucidate the influence of the oxide properties on the biological reaction. The results of animal studies using the presently characterized surface oxides on titanium implants will be published separately.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11761170     DOI: 10.1016/s0142-9612(01)00131-4

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  50 in total

Review 1.  Titanium oral implants: surface characteristics, interface biology and clinical outcome.

Authors:  Anders Palmquist; Omar M Omar; Marco Esposito; Jukka Lausmaa; Peter Thomsen
Journal:  J R Soc Interface       Date:  2010-06-30       Impact factor: 4.118

2.  Osseointegration of titanium implants with SLAffinity treatment: a histological and biomechanical study in miniature pigs.

Authors:  Keng-Liang Ou; Heng-Jui Hsu; Tzu-Sen Yang; Yun-Ho Lin; Chin-Sung Chen; Pei-Wen Peng
Journal:  Clin Oral Investig       Date:  2015-10-28       Impact factor: 3.573

3.  Formation mechanism of biomedical apatite coatings on porous titania layer.

Authors:  Ping Huang; Kewei Xu; Yong Han
Journal:  J Mater Sci Mater Med       Date:  2007-03       Impact factor: 3.896

4.  Surface characteristics and bioactivity of oxide film on titanium metal formed by thermal oxidation.

Authors:  Yeong-Joon Park; Ho-Jun Song; In Kim; Hong-So Yang
Journal:  J Mater Sci Mater Med       Date:  2007-04       Impact factor: 3.896

5.  Enhanced cell integration to titanium alloy by surface treatment with microarc oxidation: a pilot study.

Authors:  Young Wook Lim; Soon Yong Kwon; Doo Hoon Sun; Hyoun Ee Kim; Yong Sik Kim
Journal:  Clin Orthop Relat Res       Date:  2009-05-12       Impact factor: 4.176

Review 6.  Organic-inorganic surface modifications for titanium implant surfaces.

Authors:  Lise T de Jonge; Sander C G Leeuwenburgh; Joop G C Wolke; John A Jansen
Journal:  Pharm Res       Date:  2008-05-29       Impact factor: 4.200

7.  Effects of titanium surface anodization with CaP incorporation on human osteoblastic response.

Authors:  Natássia Cristina Martins Oliveira; Camilla Christian Gomes Moura; Darceny Zanetta-Barbosa; Daniela Baccelli Silveira Mendonça; Lyndon Cooper; Gustavo Mendonça; Paula Dechichi
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2013-01-11       Impact factor: 7.328

8.  Comparative osteogenesis of maxilla and iliac crest human bone marrow stromal cells attached to oxidized titanium: a pilot study.

Authors:  Sunday O Akintoye; Parascevi Giavis; Derek Stefanik; Lawrence Levin; Francis K Mante
Journal:  Clin Oral Implants Res       Date:  2008-11       Impact factor: 5.977

9.  Electrochemical growth behavior, surface properties, and enhanced in vivo bone response of TiO2 nanotubes on microstructured surfaces of blasted, screw-shaped titanium implants.

Authors:  Young-Taeg Sul
Journal:  Int J Nanomedicine       Date:  2010-04-15

10.  Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits.

Authors:  Jung-Woo Koh; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.