Literature DB >> 11761092

Haemolysis during cardiopulmonary bypass: how to reduce the free haemoglobin by managing the suctioned blood separately.

A Pierangeli1, V Masieri, F Bruzzi, E De Toni, G Grillone, P Boni, A Delnevo.   

Abstract

During cardiopulmonary bypass (CPB) the collection of the patient's blood from the operating area is of fundamental importance. This blood is collected in the cardiotomy reservoir using field suckers and can be managed in different ways. It can be filtered in the cardiotomy reservoir and redirected to the venous reservoir, then oxygenated and returned to the patient, or it can be managed separately: collected in the cardiotomy reservoir, treated at the end of the operation and only after this, returned to the patient. The aim of this study is to determine in vivo the effect of a separate management of the suction blood from the operative field, using the Avant D903 oxygenator (Dideco, Mirandola, Italy). Twenty-one patients undergoing coronary artery bypass graft surgery with CPB were selected and put into two groups at random. In the control group (n = 10) the suction blood in the cardiotomy reservoir was filtered and immediately redirected into the venous reservoir, oxygenated and returned to the patient. In the study group (n = 11) the suctioned blood was collected in the D903 Avant's (Dideco) cardiotomy reservoir and returned to the patient only after having been washed at the end of the operation, using a Compact Advanced (Dideco), as required. Clinical data demonstrated that while in the study group it was possible to keep the free plasma haemoglobin (FPH) concentrations the same as at the beginning, in the control group there was a significant increase in FPH from 5.0 +/- 3.5 mg/dl (baseline) to 37 +/- 16.7mg/dl (120min after CPB).

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11761092     DOI: 10.1177/026765910101600612

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  6 in total

1.  Classic pages of the Journal of Extracorporeal Technology.

Authors:  Jeff Riley
Journal:  J Extra Corpor Technol       Date:  2006-06

Review 2.  Optimization of the perfusion circuit and its possible impact on the inflammatory response.

Authors:  Filip De Somer
Journal:  J Extra Corpor Technol       Date:  2007-12

3.  Hemodynamic and functional assessment of patients with sickle cell disease and pulmonary hypertension.

Authors:  Anastasia Anthi; Roberto F Machado; Maria L Jison; Angelo M Taveira-Dasilva; Lewis J Rubin; Lori Hunter; Christian J Hunter; Wynona Coles; James Nichols; Nilo A Avila; Vandana Sachdev; Clara C Chen; Mark T Gladwin
Journal:  Am J Respir Crit Care Med       Date:  2007-03-22       Impact factor: 21.405

4.  Clinical evaluation of poly(2-methoxyethylacrylate) in primary coronary artery bypass grafting.

Authors:  See N Vang; Chad P Brady; Kevin A Christensen; Jack R Isler; Keith R Allen
Journal:  J Extra Corpor Technol       Date:  2005-03

Review 5.  Hemolysis in cardiac surgery patients undergoing cardiopulmonary bypass: a review in search of a treatment algorithm.

Authors:  Leen Vercaemst
Journal:  J Extra Corpor Technol       Date:  2008-12

6.  Low-Level Light Therapy Protects Red Blood Cells Against Oxidative Stress and Hemolysis During Extracorporeal Circulation.

Authors:  Tomasz Walski; Anna Drohomirecka; Jolanta Bujok; Albert Czerski; Grzegorz Wąż; Natalia Trochanowska-Pauk; Michał Gorczykowski; Romuald Cichoń; Małgorzata Komorowska
Journal:  Front Physiol       Date:  2018-05-31       Impact factor: 4.566