MAST system: a new condensed cardiopulmonary bypass circuit for adult cardiac surgery.

K McCusker1, V Vijay, W DeBois, R Helm, D Sisto.   

Abstract

There have been many refinements in cardiopulmonary bypass (CPB) techniques over the past few decades specific to design, materials and function. Despite these improvements, use of the standard length circuit tubing and pump oxygenator alter cellular, biochemical and rheological properties by inducing a systemic inflammatory response, persisting well into the early postoperative phase. We have designed a new condensed CPB circuit, the MAST system, where the oxygenator and the pumps are brought closer to the operating table (within 30 inches) with the help of a series of telescopic swivel steel poles to which they are attached. The control console is retained at the usual remote location of 2ft behind the MAST system. This configuration accomplishes a decrease in tubing length, priming volume and blood circulatory time within the extracorporeal circuit. Early experience of a hundred consecutive cases utilizing the MAST CPB system is presented along with a comparative analysis of prime volume, hemodilution and transfusion parameters of MAST system vs the low prime system, which is another newly developed CPB circuit utilizing a pediatric oxygenator to reduce prime volume and hemodilution.

Entities:  

Mesh:

Year:  2001        PMID: 11761083     DOI: 10.1177/026765910101600603

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  5 in total

1.  Understanding Off-Label Use and Reference Blood Flows in Modern Membrane Oxygenators.

Authors:  Gerard J Myers
Journal:  J Extra Corpor Technol       Date:  2014-09

2.  Going beyond manufacturers' limitations is not in the best interest of our patients.

Authors:  Gerard J Myers
Journal:  J Extra Corpor Technol       Date:  2014-03

Review 3.  Acute Kidney Injury Subsequent to Cardiac Surgery.

Authors:  Robert S Kramer; Crystal R Herron; Robert C Groom; Jeremiah R Brown
Journal:  J Extra Corpor Technol       Date:  2015-03

4.  To RAP or Not to RAP: A Retrospective Comparison of the Effects of Retrograde Autologous Priming.

Authors:  Emily Foreman; Morgan Eddy; Jenny Holdcombe; Phoebe Warren; Lisa Gebicke; Pamela Raney; Wilson Clements; James Zellner
Journal:  J Extra Corpor Technol       Date:  2021-12

5.  Prescriptive patient extracorporeal circuit and oxygenator sizing reduces hemodilution and allogeneic blood product transfusion during adult cardiac surgery.

Authors:  Shahna L Bronson; Jeffrey B Riley; Joshua P Blessing; Mark H Ereth; Joseph A Dearani
Journal:  J Extra Corpor Technol       Date:  2013-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.