Literature DB >> 11759125

The effect of nitrous oxide on laryngeal mask cuff pressure.

R G Ouellette1.   

Abstract

During general anesthesia with the laryngeal mask airway (LMA), a significant increase in cuff pressure due to diffusion of nitrous oxide through the cuff wall occurs. This descriptive clinical study was conducted in a university teaching hospital ambulatory surgical center with 100 patients (ASA physical status, I-III; age, 5 months to 76 years; weight, 5.8-146.3 kg) undergoing general anesthesia with an LMA. The airway pressure at which the LMA seal was broken (leak pressure) was determined immediately after the insertion of the LMA. The LMA leak pressure was determined by closing the circuit pop-off valve and recording with a stethoscope at the neck the pressure at which the gas was first heard to escape around the LMA. The LMA cuff pressure was determined by connecting the check valve of the LMA pilot balloon to a sphygmomanometer. The mean LMA cuff pressure increased 16 +/- 8.2 mm Hg (1- to 30-minute group), 38.11 +/- 15.87 mm Hg (31- to 60-minute group), 39.53 +/- 16.9 mm Hg (61- to 90-minute group), 42.63 +/- 20.36 mm Hg (91- to 120-minute group), and 44.25 +/- 14.03 mm Hg (120- to 350-minute group). This study demonstrated that there was a gradual increase in the cuff pressure well over a 3-hour period during nitrous oxide and oxygen anesthesia.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11759125

Source DB:  PubMed          Journal:  AANA J        ISSN: 0094-6354


  9 in total

1.  A preliminary study of I-gel: a new supraglottic airway device.

Authors:  Ashish Kannaujia; Uma Srivastava; Namita Saraswat; Abhijeet Mishra; Aditya Kumar; Surekha Saxena
Journal:  Indian J Anaesth       Date:  2009-02

2.  I-gel versus laryngeal mask airway-Proseal: Comparison of two supraglottic airway devices in short surgical procedures.

Authors:  Poonam A Jadhav; Naina P Dalvi; Bharati A Tendolkar
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Apr-Jun

3.  Comparison of i-gel™ and laryngeal mask airway Classic™ in terms of ease of insertion and hemodynamic response: A randomized observational study.

Authors:  N Pratheeba; G S Ramya; R V Ranjan; R Remadevi
Journal:  Anesth Essays Res       Date:  2016 Sep-Dec

Review 4.  Optimal dose of succinylcholine for laryngeal mask airway insertion: systematic review, meta-analysis and metaregression of randomised control trials.

Authors:  Alan Hsi-Wen Liao; Yu-Cih Lin; Chyi-Huey Bai; Chien-Yu Chen
Journal:  BMJ Open       Date:  2017-08-04       Impact factor: 2.692

5.  Comparison of success rate of BlockBuster® versus Fastrach® LMA as conduit for blind endotracheal intubation: A prospective randomised trial.

Authors:  Archana Endigeri; Anilkumar Ganeshnavar; Bvs Varaprasad; Y H Shivanand; Basavaraja Ayyangouda
Journal:  Indian J Anaesth       Date:  2019-12-11

6.  Effect of diffusion of anaesthetic gases on fibre-optic view change of laryngeal mask airway and post-operative laryngo-pharyngeal morbidity in children - A randomised controlled trial.

Authors:  Neerja Bharti; Indu Bala; Revathi Lokala; Neeru Sahni; Ram Samujh
Journal:  Indian J Anaesth       Date:  2021-10-08

7.  Comparison of clinical performance of the I-gel with LMA proseal.

Authors:  Gaurav Chauhan; Pavan Nayar; Anita Seth; Kapil Gupta; Mamta Panwar; Nidhi Agrawal
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01

8.  Extraglottic airway devices: A review.

Authors:  Ramesh Ramaiah; Debasmita Das; Sanjay M Bhananker; Aaron M Joffe
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01

Review 9.  Small is the new big: An overview of newer supraglottic airways for children.

Authors:  Rakhee Goyal
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Oct-Dec
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.