Literature DB >> 11758980

Iris-claw phakic intraocular lens for high myopia.

M Landesz1, G van Rij, G Luyten.   

Abstract

PURPOSE: To evaluate the efficacy, safety, predictability, and stability of implanting a polymethylmethacrylate (PMMA) phakic intraocular lens (PIOL) (the Artisan myopia lens) to correct high myopia.
METHODS: An Artisan myopia lens was implanted in 78 consecutive eyes of 49 patients with preoperative myopia that ranged from -6.25 to -28.00 D. Mean patient age was 42.4 years. Mean follow-up was 10.7 months and all patients were followed for at least 6 months; 45 eyes had follow-up of 12 months, and 10 eyes had 24 months. The desired outcome was emmetropia in all eyes except for those eyes with preoperative myopia greater then -23.00 D.
RESULTS: Fifty-three eyes (67.9%) had a postoperative refraction at the last follow-up examination within +/-1.00 D of emmetropia, and 39 eyes (50.0%) had a postoperative refraction +/- within 0.50 D of emmetropia. The postoperative refraction remained stable during the entire follow-up period. Mean spectacle-corrected visual acuity improved from 20/32 preoperatively to 20/25 postoperatively. Mean postoperative uncorrected visual acuity was 20/32. There was no significant change in endothelial cell density from baseline. We did not encounter major complications.
CONCLUSION: Implantation of the Artisan myopia lens to correct high myopia resulted in a stable and fairly predictable refractive outcome. A significant endothelial cell change was not detected.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11758980     DOI: 10.3928/1081-597X-20011101-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  8 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

Review 2.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

4.  Long-term endothelial cell loss with the iris-claw intraocular phakic lenses (Artisan®).

Authors:  Virgilio Galvis; John F Villamil; María Fernanda Acuña; Paul A Camacho; Jesús Merayo-Lloves; Alejandro Tello; Sandra Lizeth Zambrano; Juan José Rey; Juan Vicente Espinoza; Angélica María Prada
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-10-28       Impact factor: 3.117

5.  Five-year follow-up after anterior iris-fixated intraocular lens implantation in phakic eyes to correct high myopia.

Authors:  X Yuan; H Z Ping; W C Hong; D Yin; Z Ting
Journal:  Eye (Lond)       Date:  2011-12-02       Impact factor: 3.775

Review 6.  [Toric phakic intraocular lenses].

Authors:  H B Dick; S E Buchner
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

7.  A retrospective analysis of the first Yemeni experience on Artisan phakic intraocular lens for the treatment of moderate and high myopia.

Authors:  Mahfouth A Bamashmus; Awadalla A Mohamed; Hisham A Alakhlee
Journal:  Oman J Ophthalmol       Date:  2012-09

8.  Foldable iris-fixated phakic intraocular lens implantation for the correction of myopia: two years of follow-up.

Authors:  Yusuf Ozertürk; Anil Kubaloglu; Esin Sogutlu Sari; Arif Koytak; Musa Capkin; Levent Akçay; Pinar Sorgun Evcili
Journal:  Indian J Ophthalmol       Date:  2012 Jan-Feb       Impact factor: 1.848