Literature DB >> 11757613

Further developments in the use of semipermeable membrane devices as passive air samplers: application to PCBs.

W A Ockenden1, B P Corrigan, M Howsam, K C Jones.   

Abstract

There are several incentives for developing passive air sampling techniques for persistent organic pollutants (POPs). This paper reports on studies to further calibrate and optimize semipermeable membrane devices (SPMDs) for use as "integrated" air samplers of gas-phase POPs. These samplers are deployed over weeks/months/years. Polychlorinated biphenyls (PCBs) were used as the test compounds in this study, with three specific objectives: (i) to determine whether ambient wind speed limits the rate of uptake during typical deployment conditions; (ii) to monitor uptake and SPMD-air equilibrium for a range of compounds; and (iii) to assess the application of performance reference compounds (PRCs) in air sampling, to "correct" for site-specific differences in uptake rates. When deployed in Stevensons screens under ambient conditions, wind speed did not significantly affect uptake rates. Rather, differences in summer/winter uptake rates reported previously, using the same deployment devices as here, are due to temperature affecting compound permeability through the membrane. Results from the use of PRCs indicate that SPMDs should be spiked prior to exposure with a range of compounds that are not present in the atmosphere, so that uptake rates can be estimated from depuration rates during a particular deployment. Short-term deployments (e.g. days; few weeks) would need to use compound(s) with a low octanol:air partition coefficient (K(OA)) (e.g. 13C12 labeled PCB-28); long-term deployments (of many months to years) would need to use intermediate K(OA) compounds (e.g. 13C12 PCB-101; 13C12 PCB-153).

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11757613     DOI: 10.1021/es0101126

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  3 in total

1.  Partitioning of fluorotelomer alcohols (FTOH) to semipermeable membrane devices (SPMD).

Authors:  Stefan Fiedler; Gerd Pfister; Karl-Werner Schramm
Journal:  Environ Sci Pollut Res Int       Date:  2009-09-17       Impact factor: 4.223

2.  Analytical methods for PCBs and organochlorine pesticides in environmental monitoring and surveillance: a critical appraisal.

Authors:  Derek Muir; Ed Sverko
Journal:  Anal Bioanal Chem       Date:  2006-09-20       Impact factor: 4.142

3.  Comparison of lichen, conifer needles, passive air sampling devices, and snowpack as passive sampling media to measure semi-volatile organic compounds in remote atmospheres.

Authors:  Jill E Schrlau; Linda Geiser; Kimberly J Hageman; Dixon H Landers; Staci Massey Simonich
Journal:  Environ Sci Technol       Date:  2011-11-16       Impact factor: 9.028

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.