Literature DB >> 11756166

Shear-dependent tether formation during platelet translocation on von Willebrand factor.

Sacha M Dopheide1, Mhairi J Maxwell, Shaun P Jackson.   

Abstract

The adhesion and aggregation of platelets at sites of vascular injury is dependent on the initial binding of the GP Ib/V/IX receptor complex to immobilized von Willebrand factor (VWF). Under flow conditions, this interaction supports platelet translocation that is characteristically stop-start in nature. High resolution imaging of platelets during surface translocation on immobilized VWF revealed that thin membrane tethers (length: 0.91 microm-47.90 microm) were pulled from the surface of these cells. Membrane tethers were dynamic structures that extended from small, localized adhesion contacts under the influence of flow. Perfusion of platelets in the presence of blocking antibodies against integrin alpha(IIb)beta(3), or over isolated A1 domains, demonstrated that the VWF-GP Ib interaction was sufficient to induce membrane tether formation. The rate and extent of tether elongation was shear-dependent (shear range: 150 s(-1)-10,000 s(-1)), with mean tether length ranging from 3.23 microm to 16.55 microm, tether frequency from 2.67% to 97.33%, and tether growth rate from 0.04 microm/sec to 8.39 microm/sec. Tether formation and retraction did not require platelet activation; however, the growth rate, lifetime, and dimensions were significantly affected by the actin polymerization inhibitor, cytochalasin D, and by chelating intracellular calcium. Single-cell analysis revealed that formation of membrane tethers regulates the stop-start phases of platelet translocation on VWF, suggesting a potentially important role for this phenomenon in regulating the dynamics of the platelet-VWF interaction under flow.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11756166     DOI: 10.1182/blood.v99.1.159

Source DB:  PubMed          Journal:  Blood        ISSN: 0006-4971            Impact factor:   22.113


  36 in total

1.  Dynamic alterations of membrane tethers stabilize leukocyte rolling on P-selectin.

Authors:  Vishwanath Ramachandran; Marcie Williams; Tadayuki Yago; David W Schmidtke; Rodger P McEver
Journal:  Proc Natl Acad Sci U S A       Date:  2004-09-07       Impact factor: 11.205

2.  Haemodynamic forces on in vitro thrombi: a numerical analysis.

Authors:  Christopher J Butler; Kris Ryan; Gregory J Sheard
Journal:  Med Biol Eng Comput       Date:  2012-03-16       Impact factor: 2.602

Review 3.  Which anti-platelet therapies might be beneficial in xenotransplantation?

Authors:  Moritz Schmelzle; Peter J Cowan; Simon C Robson
Journal:  Xenotransplantation       Date:  2011 Mar-Apr       Impact factor: 3.907

4.  In the shadow of the thrombus.

Authors:  Lawrence Brass
Journal:  Nat Med       Date:  2009-06       Impact factor: 53.440

5.  Dok-2 adaptor protein regulates the shear-dependent adhesive function of platelet integrin αIIbβ3 in mice.

Authors:  Sascha C Hughan; Christopher M Spring; Simone M Schoenwaelder; Sharelle Sturgeon; Imala Alwis; Yuping Yuan; James D McFadyen; Erik Westein; Duncan Goddard; Akiko Ono; Yuji Yamanashi; Warwick S Nesbitt; Shaun P Jackson
Journal:  J Biol Chem       Date:  2014-01-02       Impact factor: 5.157

6.  Platelet interaction with von Willebrand factor is enhanced by shear-induced clustering of glycoprotein Ibα.

Authors:  Eelo Gitz; Charlotte D Koopman; Alèkos Giannas; Cornelis A Koekman; Dave J van den Heuvel; Hans Deckmyn; Jan-Willem N Akkerman; Hans C Gerritsen; Rolf T Urbanus
Journal:  Haematologica       Date:  2013-06-10       Impact factor: 9.941

7.  The class II PI 3-kinase, PI3KC2α, links platelet internal membrane structure to shear-dependent adhesive function.

Authors:  Jessica K Mountford; Claire Petitjean; Harun W Kusuma Putra; Jonathan A McCafferty; Natasha M Setiabakti; Hannah Lee; Lotte L Tønnesen; James D McFadyen; Simone M Schoenwaelder; Anita Eckly; Christian Gachet; Sarah Ellis; Anne K Voss; Ross A Dickins; Justin R Hamilton; Shaun P Jackson
Journal:  Nat Commun       Date:  2015-03-17       Impact factor: 14.919

8.  Microfluidic measurement for blood flow and platelet adhesion around a stenotic channel: Effects of tile size on the detection of platelet adhesion in a correlation map.

Authors:  Sung Yong Jung; Eunseop Yeom
Journal:  Biomicrofluidics       Date:  2017-04-25       Impact factor: 2.800

9.  Tangential tether extraction and spontaneous tether retraction of human neutrophils.

Authors:  Baoyu Liu; Jin-Yu Shao
Journal:  Biophys J       Date:  2012-12-05       Impact factor: 4.033

10.  VAMP-7 links granule exocytosis to actin reorganization during platelet activation.

Authors:  Secil Koseoglu; Christian G Peters; Jennifer L Fitch-Tewfik; Omozuanvbo Aisiku; Lydia Danglot; Thierry Galli; Robert Flaumenhaft
Journal:  Blood       Date:  2015-05-21       Impact factor: 22.113

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.