Effects of k-space filtering and image interpolation on image fidelity in (1)H MRSI.

B Vikhoff-Baaz1, G Starck, M Ljungberg, K Lagerstrand, E Forssell-Aronsson, S Ekholm.   

Abstract

2D MRSI suffers from the effect of the spatial response function due to the truncation of the sampling of k-space. Filtering of the k-space data-set is often used to suppress the side lobes caused by the effects of the SRF, where the sampled data-set is multiplied with a weighting function before inverse FT. Commonly used filters in MRSI are the cosine, Hanning and Hamming filters. The data-set is often interpolated into a larger image matrix size for analysis, where "Fourier interpolation" (FoI) and "cubic spline interpolation" (CSpI) are two common methods. In this work, the effects of k-space filtering in practical usage was examined, and the image representations of the object for the two interpolation methods were compared. This study showed that application of filtering improves the image representation of the structures in the object and should be used in MRSI. FoI correctly visualizes the information inherent in the data-set, while the features of the object were dependent on the position of the object relative the original matrix in the CSpI interpolated images. FoI should therefore be used for quantitative evaluation of MRSI images.

Entities:  

Mesh:

Year:  2001        PMID: 11755733     DOI: 10.1016/s0730-725x(01)00456-8

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  On precise localization of boundaries between extended uniform objects in MRI: tooth imaging as an example.

Authors:  Olga Tymofiyeva; Florian Schmid; Markus von Kienlin; Felix A Breuer; Kurt Rottner; Julian Boldt; Ernst-Juergen Richter; Peter M Jakob
Journal:  MAGMA       Date:  2010-09-29       Impact factor: 2.310

2.  Investigation of the PSF-choice method for reduced lipid contamination in prostate MR spectroscopic imaging.

Authors:  Lawrence P Panych; Joseph R Roebuck; Nan-kuei Chen; Yi Tang; Bruno Madore; Clare M Tempany; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2012-11       Impact factor: 4.668

3.  Hemi-spectrum substitution after water signal fitting (HESWAF): an improvement of the modulus post-processing of MR spectra.

Authors:  Yann Le Fur; Patrick J Cozzone
Journal:  MAGMA       Date:  2014-06-03       Impact factor: 2.310

4.  Influence of injection rate in determining the development of artifacts during the acquisition of dynamic arterial phase in Gd-EOB-DTPA MRI studies.

Authors:  Davide Ippolito; Cesare Maino; Anna Pecorelli; Luca Riva; Giulia Querques; Cammillo Talei Franzesi; Sandro Sironi
Journal:  MAGMA       Date:  2020-06-19       Impact factor: 2.310

5.  Phosphorus-31 two-dimensional chemical shift imaging in the myocardium of patients with late onset of Friedreich ataxia.

Authors:  Christian Wolf; Sylvia Boesch; Bernhard Metzler; Helga Weirich-Schwaiger; Thomas Trieb; Michael F H Schocke
Journal:  Mol Imaging Biol       Date:  2007-11-14       Impact factor: 3.488

6.  Repeatability of (31) P MRSI in the human brain at 7 T with and without the nuclear Overhauser effect.

Authors:  Miriam W Lagemaat; Bart L van de Bank; Pascal Sati; Shizhe Li; Marnix C Maas; Tom W J Scheenen
Journal:  NMR Biomed       Date:  2015-12-08       Impact factor: 4.044