The usefulness of a 10% air-10% blood-80% saline mixture for contrast echocardiography: Doppler measurement of pulmonary artery systolic pressure.

Doo-Soo Jeon1, Huai Luo, Takahiro Iwami, Takashi Miyamoto, Andrea V Brasch, James Mirocha, Tasneem Z Naqvi, Robert J Siegel.   

Abstract

OBJECTIVES: We assessed an air-blood-saline mixture for Doppler measurement of pulmonary artery systolic pressure (PASP) and the mechanism of enhancement of the Doppler signal by this mixture.
BACKGROUND: Underestimation of PASP by Doppler echocardiography occurs with inadequate continuous wave (CW) signals of tricuspid regurgitation (TR).
METHODS: We assessed in vitro the diameter and concentration of microbubbles of agitated air-saline mixture, air-blood-saline mixture and 10% air-10% plasma-80% saline mixture immediately, 5, 10 and 20 s after agitation. In 20 patients, PASP was estimated by Swan-Ganz catheter and CW Doppler of TR: 1) without contrast injection; 2) with intravenous injection of 10% air-90% saline; and 3) 10% blood-10% air-80% saline mixture.
RESULTS: Compared to air-saline, addition of blood or plasma to the air-saline solution significantly increased the concentration of microbubbles (p < 0.001). The air-blood-saline (26.7 +/- 7.2 microm) and air-plasma-saline mixture (25.3 +/- 7.4 microm) had smaller microbubbles than air-saline mixture (31.6 +/- 8.2 microm) (p < 0.001). The correlation between Doppler- and catheter-measured PASP at baseline (r = 0.64) improved with agitated air-saline (r = 0.86). With the air-blood-saline mixture, the correlation further improved (r = 0.92) and the best limits of agreement were obtained.
CONCLUSIONS: The combination of the patient's own blood is a method of making a sterile solution of numerous small microbubbles for injection into the right-sided cardiac chambers. Clinically, the air-blood-saline mixture is easily prepared at bedside and is superior to the air-saline mixture in assessing PASP in patients with inadequate CW Doppler signals.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11755297     DOI: 10.1016/s0735-1097(01)01698-9

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  16 in total

1.  Safety of echocardiographic contrast in hospitalized patients with pulmonary hypertension: a multi-center study.

Authors:  Omar Wever-Pinzon; Valentin Suma; Ameeta Ahuja; Jorge Romero; Nishtha Sareen; Sonia A Henry; Maria De Benedetti Zunino; Farhan F Chaudhry; Ramya S Suryadevara; Mark V Sherrid; Farooq A Chaudhry
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2012-03-16       Impact factor: 6.875

2.  Assessment of pulmonary arterial hypertension and vascular resistance by measurements of the pulmonary arterial flow velocity curve in the absence of a measurable tricuspid regurgitant velocity in childhood congenital heart disease.

Authors:  Ayhan Cevik; Serdar Kula; Rana Olgunturk; F Sedef Tunaoglu; A Deniz Oguz; Berna Saylan; Erman Cilsal; Cihat Sanli
Journal:  Pediatr Cardiol       Date:  2012-10-05       Impact factor: 1.655

3.  Accuracy of Echocardiography to Estimate Pulmonary Artery Pressures With Exercise: A Simultaneous Invasive-Noninvasive Comparison.

Authors:  Annelieke C M J van Riel; Alexander R Opotowsky; Mário Santos; Jose M Rivero; Andy Dhimitri; Barbara J M Mulder; Berto J Bouma; Michael J Landzberg; Aaron B Waxman; David M Systrom; Amil M Shah
Journal:  Circ Cardiovasc Imaging       Date:  2017-04       Impact factor: 7.792

4.  AltitudeOmics: effect of reduced barometric pressure on detection of intrapulmonary shunt, pulmonary gas exchange efficiency, and total pulmonary resistance.

Authors:  Frank A Petrassi; James T Davis; Kara M Beasley; Oghenero Evero; Jonathan E Elliott; Randall D Goodman; Joel E Futral; Andrew Subudhi; J Manuel Solano-Altamirano; Saul Goldman; Robert C Roach; Andrew T Lovering
Journal:  J Appl Physiol (1985)       Date:  2017-12-14

Review 5.  [Standardized contrast-enhanced ultrasound (CEUS) in clinical acute and emergency medicine and critical care (CEUS Acute) : Consensus statement of DGIIN, DIVI, DGINA, DGAI, DGK, ÖGUM, SGUM and DEGUM].

Authors:  Guido Michels; Rudolf Horn; Andreas Helfen; Andreas Hagendorff; Christian Jung; Beatrice Hoffmann; Natalie Jaspers; Horst Kinkel; Clemens-Alexander Greim; Fabian Knebel; Johann Bauersachs; Hans-Jörg Busch; Daniel Kiefl; Alexander O Spiel; Gernot Marx; Christoph F Dietrich
Journal:  Med Klin Intensivmed Notfmed       Date:  2022-02       Impact factor: 0.840

6.  Is bacteriostatic saline superior to normal saline as an echocardiographic contrast agent?

Authors:  Shaun Cardozo; Prasad Gunasekaran; Hena Patel; Timothy McGorisk; Mehrdad Toosi; Haroon Faraz; Sandip Zalawadiya; Issa Alesh; Anupama Kottam; Luis Afonso
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-15       Impact factor: 2.357

7.  Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles.

Authors:  Hanwook Park; Eunseop Yeom; Seung-Jun Seo; Jae-Hong Lim; Sang-Joon Lee
Journal:  Sci Rep       Date:  2015-03-06       Impact factor: 4.379

8.  In vivo measurement of hemodynamic information in stenosed rat blood vessels using X-ray PIV.

Authors:  Hanwook Park; Jun Hong Park; Sang Joon Lee
Journal:  Sci Rep       Date:  2016-11-28       Impact factor: 4.379

9.  The usefulness of contrast during exercise echocardiography for the assessment of systolic pulmonary pressure.

Authors:  Luis R Lopes; Maria J Loureiro; Rita Miranda; Sofia Almeida; Ana R Almeida; Ana Cordeiro; Carlos Cotrim; Manuel Carrageta
Journal:  Cardiovasc Ultrasound       Date:  2008-10-13       Impact factor: 2.062

10.  X-ray PIV measurement of blood flow in deep vessels of a rat: An in vivo feasibility study.

Authors:  Hanwook Park; Eunseop Yeom; Sang Joon Lee
Journal:  Sci Rep       Date:  2016-01-18       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.