Literature DB >> 11754257

Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format.

Tasso Miliotis1, Sven Kjellström, Johan Nilsson, Thomas Laurell, Lars-Erik Edholm, György Marko-Varga.   

Abstract

The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 microm. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded. Copyright 2001 John Wiley & Sons, Ltd.

Entities:  

Year:  2002        PMID: 11754257     DOI: 10.1002/rcm.542

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  6 in total

1.  On-line single droplet deposition for MALDI mass spectrometry.

Authors:  Xia Zhang; Damien A Narcisse; Kermit K Murray
Journal:  J Am Soc Mass Spectrom       Date:  2004-10       Impact factor: 3.109

2.  Comparison between vacuum sublimed matrices and conventional dried droplet preparation in MALDI-TOF mass spectrometry.

Authors:  Thorsten W Jaskolla; Michael Karas; Udo Roth; Kerstin Steinert; Christoph Menzel; Karsten Reihs
Journal:  J Am Soc Mass Spectrom       Date:  2009-02-12       Impact factor: 3.109

3.  Matrix precoated targets for direct lipid analysis and imaging of tissue.

Authors:  Junhai Yang; Richard M Caprioli
Journal:  Anal Chem       Date:  2013-02-18       Impact factor: 6.986

4.  Matrix pre-coated targets for high throughput MALDI imaging of proteins.

Authors:  Junhai Yang; Richard M Caprioli
Journal:  J Mass Spectrom       Date:  2014-05       Impact factor: 1.982

5.  Miniaturizing sample spots for matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Tingting Tu; Michael L Gross
Journal:  Trends Analyt Chem       Date:  2009-08-01       Impact factor: 12.296

6.  Clinical initiatives linking Japanese and Swedish healthcare resources on cancer studies utilizing Biobank Repositories.

Authors:  Toshihide Nishimura; Takeshi Kawamura; Yutaka Sugihara; Yasuhiko Bando; Shigeru Sakamoto; Masaharu Nomura; Norihiko Ikeda; Tatsuo Ohira; Junichiro Fujimoto; Hiromasa Tojo; Takao Hamakubo; Tatsuhiko Kodama; Roland Andersson; Thomas E Fehniger; Harubumi Kato; György Marko-Varga
Journal:  Clin Transl Med       Date:  2014-11-22
  6 in total