Abstract

RATIONALE AND
OBJECTIVES: The purpose was to compare differences in the depiction of small vessels in tumors seen on microangiograms from a conventional soft x-ray system with those from a synchrotron radiation system and to evaluate the microangioarchitecture of these tumors and the growth of neovascularization.
METHODS: VX2 carcinomas transplanted to the auricles of 15 rabbits randomized into three groups were investigated after 1, 3, and 7 days. Five normal rabbits were the controls. Barium sulfate, to which sufficient gelatin had been added, was injected into the auricular artery. Microangiograms of auricle specimens were obtained with both a conventional soft x-ray system and a synchrotron radiation system.
RESULTS: The conventional x-ray system could detect vessels with diameters of approximately 100 microm, whereas the monochromatic synchrotron radiation system could detect small vessels with diameters of less than 25 microm. On day 1, there was moderate vascularization and flexure vessels were present in the transplantation area. On day 3, dilated vessels were present in the peripheral areas of the tumors and tortuous vessels in the central areas. On day 7, hypovascular areas had increased in the central area.
CONCLUSIONS: The synchrotron radiation system confirmed the growth of neovascularization in the tumors. This system should provide a useful tool for evaluating the microangioarchitecture of tumors.

Entities:  

Mesh:

Year:  2001        PMID: 11753142     DOI: 10.1097/00004424-200112000-00006

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  Three-dimensional characterization of the vascular bed in bone metastasis of the rat by microcomputed tomography (MicroCT).

Authors:  Hervé Nyangoga; Philippe Mercier; Hélène Libouban; Michel Félix Baslé; Daniel Chappard
Journal:  PLoS One       Date:  2011-03-28       Impact factor: 3.240

2.  Evaluating the effect of Avastin on breast cancer angiogenesis using synchrotron radiation.

Authors:  Shengmei Gu; Jingyan Xue; Yan Xi; Rongbiao Tang; Wei Jin; Jia-Jian Chen; Xi Zhang; Zhi-Min Shao; Jiong Wu
Journal:  Quant Imaging Med Surg       Date:  2019-03

3.  Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema.

Authors:  Hiromichi Ito; Shonosuke Matsushita; Kazuyuki Hyodo; Yukio Sato; Yuzuru Sakakibara
Journal:  J Synchrotron Radiat       Date:  2013-02-08       Impact factor: 2.616

4.  Neovascularization of hepatocellular carcinoma in a nude mouse orthotopic liver cancer model: a morphological study using X-ray in-line phase-contrast imaging.

Authors:  Beilei Li; Yiqiu Zhang; Weizhong Wu; Guohao Du; Liang Cai; Hongcheng Shi; Shaoliang Chen
Journal:  BMC Cancer       Date:  2017-01-25       Impact factor: 4.430

5.  Analysis of the microvascular morphology and hemodynamics of breast cancer in mice using SPring-8 synchrotron radiation microangiography.

Authors:  Masae Torii; Toshifumi Fukui; Masashi Inoue; Shotaro Kanao; Keiji Umetani; Mikiyasu Shirai; Tadakatsu Inagaki; Hirotsugu Tsuchimochi; James T Pearson; Masakazu Toi
Journal:  J Synchrotron Radiat       Date:  2017-08-02       Impact factor: 2.616

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.