Literature DB >> 11752229

The single laser flow cytometric micronucleus test: a time course study using colchicine and urethane in rat and mouse peripheral blood and acetaldehyde in rat peripheral blood.

G M Hynes1, D K Torous, C R Tometsko, B Burlinson, D G Gatehouse.   

Abstract

A single laser flow cytometric procedure to quantify micronucleus frequency in rat and mouse peripheral blood was evaluated. Reticulocytes express the transferrin receptor (also known as the CD71-defined antigen). When combined with a DNA stain, antibodies against this antigen can be used to differentially label and quantify micronucleated reticulocytes. The object of this study was to evaluate the method for rat and mouse peripheral blood using flow cytometry and compare the results obtained between two laboratories (GlaxoWellcome and Litron Laboratories). The compounds selected were the rodent carcinogens colchicine, urethane and acetaldehyde. Colchicine gives a positive response in the rat bone marrow micronucleus assay and an inconclusive result in the rat peripheral blood micronucleus assay. The latter two are both established rat carcinogens readily detected in both the bone marrow and peripheral blood micronucleus assays. In these experiments both rat and mice were treated with either colchicine or urethane and rats alone treated with acetaldehyde. After a single treatment, repeat sampling of peripheral blood was made at 0, 24, 48 and 72 h. Replicate blood samples were obtained and fixed for flow cytometric analysis at both facilities. The micronucleated reticulocyte frequency of each blood sample was determined by analysing 20 000 total reticulocytes per blood sample. The data suggest that the single laser flow cytometric procedure resulted in consistent reticulocyte and micronucleated reticulocyte frequencies between laboratories. Furthermore, these flow cytometric data compare favourably with previously published data.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11752229     DOI: 10.1093/mutage/17.1.15

Source DB:  PubMed          Journal:  Mutagenesis        ISSN: 0267-8357            Impact factor:   3.000


  2 in total

1.  Reticulocyte and micronucleated reticulocyte responses to gamma irradiation: dose-response and time-course profiles measured by flow cytometry.

Authors:  Stephen D Dertinger; Ying Tsai; Irena Nowak; Ollivier Hyrien; Hongliang Sun; Jeffrey C Bemis; Dorothea K Torous; Peter Keng; James Palis; Yuhchyau Chen
Journal:  Mutat Res       Date:  2007-07-05       Impact factor: 2.433

2.  Automated human blood micronucleated reticulocyte measurements for rapid assessment of chromosomal damage.

Authors:  Stephen D Dertinger; Richard K Miller; Kelly Brewer; Therese Smudzin; Dorothea K Torous; Daniel J Roberts; Svetlana L Avlasevich; Steven M Bryce; Siva Sugunan; Yuhchyau Chen
Journal:  Mutat Res       Date:  2006-10-23       Impact factor: 2.433

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.