Literature DB >> 11752069

Evaluation of left ventricular function using electrocardiographically gated myocardial SPECT with (123)I-labeled fatty acid analog.

M Nanasato1, A Ando, S Isobe, M Nonokawa, H Hirayama, N Tsuboi, T Ito, M Hirai, M Yokota, H Saito.   

Abstract

UNLABELLED: Electrocardiographically (ECG) gated myocardial SPECT with (99m)Tc-tetrofosmin has been used widely to assess left ventricular (LV) function. However, the accuracy of variables using ECG gated myocardial SPECT with beta-methyl-p-(123)I-iodophenylpentadecanoic acid (BMIPP) has not been well defined.
METHODS: Thirty-six patients (29 men, 7 women; mean age, 61.6 +/- 15.6 y) with ischemic heart disease underwent ECG gated myocardial SPECT with (123)I-BMIPP and with (99m)Tc-tetrofosmin and left ventriculography (LVG) within 1 wk. LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), and LV end-systolic volume (LVESV) were determined on gated SPECT using commercially available software for automatic data analysis. These volume-related items on LVG were calculated with an area-length method and were estimated by 2 independent observers to evaluate interobserver validity. The regional wall motion with these methods was assessed visually.
RESULTS: LVEF was 41.1% +/- 12.5% on gated SPECT with (123)I-BMIPP, 44.5% +/- 13.1% on gated SPECT with (99m)Tc-tetrofosmin, and 46.0% +/- 12.7% on LVG. Global LV function and regional wall motion between both gated SPECT procedures had excellent correlation (LVEF, r = 0.943; LVEDV, r = 0.934; LVESV, r = 0.952; regional wall motion, kappa = 0.92). However, the correlations of global LV function and regional wall motion between each gated SPECT and LVG were significantly lower. Gated SPECT with (123)I-BMIPP showed the same interobserver validity as gated SPECT with (99m)Tc-tetrofosmin.
CONCLUSION: Gated SPECT with (123)I-BMIPP provides high accuracy with regard to LV function and is sufficiently applicable for use in clinical SPECT. This technique can simultaneously reveal myocardial fatty acid metabolism and LV function, which may be useful to evaluate various cardiac diseases.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11752069

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  8 in total

Review 1.  Gated SPECT in assessment of regional and global left ventricular function: major tool of modern nuclear imaging.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

Review 2.  Diagnostic and prognostic value of BMIPP imaging.

Authors:  Taishiro Chikamori; Akira Yamashina; Satoshi Hida; Tsunehiko Nishimura
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

3.  Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach.

Authors:  Guido Germano; Paul B Kavanagh; Piotr J Slomka; Serge D Van Kriekinge; Geoff Pollard; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

Review 4.  The Japanese experience with metabolic imaging in the clinical setting.

Authors:  Nagara Tamaki; Koichi Morita; Yuko Kawai
Journal:  J Nucl Cardiol       Date:  2007 May-Jun       Impact factor: 5.952

5.  Prognostic value of I-123 15-(p-iodophenyl)-3-(R,S) methylpentadecanoic acid myocardial imaging in patients with known or suspected coronary artery disease.

Authors:  Taishiro Chikamori; Hiroshi Fujita; Mamoru Nanasato; Masahiro Toba; Tsunehiko Nishimura
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

6.  Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis.

Authors:  Chisato Kondo; Kenji Fukushima; Kiyoko Kusakabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

7.  Predictive value of electrocardiography-gated myocardial perfusion imaging to new-onset heart failure in patients with chronic kidney disease: findings from the J-ACCESS 3 study.

Authors:  Mamoru Nanasato; Shinro Matsuo; Kenichi Nakajima; Shigeyuki Nishimura; Tsunehiko Nishimura
Journal:  Int J Cardiovasc Imaging       Date:  2020-02-15       Impact factor: 2.357

8.  Left ventricular ejection fraction measurements: accuracy and prognostic implications in a large population of patients with known or suspected ischemic heart disease.

Authors:  Alessia Gimelli; Patrizia Landi; Paolo Marraccini; Rosa Sicari; Paolo Frumento; Antonio L'Abbate; Daniele Rovai
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-09       Impact factor: 2.357