Effects of iterative reconstruction on image contrast and lesion detection in gamma camera coincidence imaging in lung and breast cancers.

A K Paul1, M Tatsumi, K Yutani, K Fujino, K Hashikawa, T Nishimura.   

Abstract

To investigate the effects of iterative reconstruction in 18F-fluorodeoxyglucose (FDG) gamma camera coincidence imaging (GCI), image contrast and visual detection obtained by using the iterative ordered-subsets expectation maximization (OSEM) reconstruction, in a phantom and in patients with lung cancer and breast cancer, were compared with those obtained by using the conventional filtered backprojection (FBP) reconstruction. Images of a cylindrical phantom containing hot spheres of various sizes (10-38 mm) were acquired by positron emission tomography (PET) and GCI at various sphere-to-background activity ratios. Forty-one consecutive patients with biopsy-proven cancer of lung (n = 20) and breast (n = 21) underwent PET and GCI on the same day after intravenous injection of 370 MBq of FDG. GCI images reconstructed by the OSEM and the FBP were compared. FDG PET was considered as the standard of reference. In GCI phantom images, OSEM yielded better contrast and signal-to-noise ratio (SNR) than FBP over the range of sphere sizes. Attenuation correction improved both the image measures and sphere detection obtained by the OSEM in GCI. In the study involving patients, FDG PET depicted 41 primary tumours and 25 metastatic lymph nodes. All of the tumours >2 cm in diameter (n = 25), six of the nine tumours 1.5-2.0 cm in diameter (67%), two of seven tumours <1.5 cm in diameter (29%), and 20 metastatic lymph nodes (80%) were detected in attenuation uncorrected GCI reconstructed by the OSEM as well as the FBP. The undetected lesions in GCI were identical between the OSEM and the FBP reconstructions. OSEM yielded significantly greater tumour-to-background (T/B) ratios and lower noise than FBP in GCI (T/B ratios, 4.1+/-3.2 vs 3.7+/-2.7, P = 0.02; noise, 0.09+/-0.04 vs 0.14+/-0.05, P<0.0001). In conclusion, OSEM yielded better image contrast and less noise than the FBP in GCI, but the lesion detection obtained by the OSEM and the FBP in attenuation uncorrected GCI in patients with lung cancer and breast cancer were similar. Phantom data suggest the potential of OSEM for improving lesion detection in GCI after attenuation correction.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11748445     DOI: 10.1097/00006231-200201000-00016

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  3 in total

1.  A matter of collection and detection for intraoperative and noninvasive near-infrared fluorescence molecular imaging: to see or not to see?

Authors:  Banghe Zhu; John C Rasmussen; Eva M Sevick-Muraca
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

2.  Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study.

Authors:  Fabrice Gutman; Isabelle Gardin; Nicolas Delahaye; Hervé Rakotonirina; Anne Hitzel; Alain Manrique; Dominique Le Guludec; Pierre Véra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-23       Impact factor: 9.236

3.  Determining the Performance of Fluorescence Molecular Imaging Devices Using Traceable Working Standards With SI Units of Radiance.

Authors:  Banghe Zhu; John C Rasmussen; Maritoni Litorja; Eva M Sevick-Muraca
Journal:  IEEE Trans Med Imaging       Date:  2015-11-03       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.