Literature DB >> 11747887

New least squares solutions for estimating the average centre of rotation and the axis of rotation.

Sahan S Hiniduma Udugama Gamage1, Joan Lasenby.   

Abstract

A new method is proposed for estimating the parameters of ball joints, also known as spherical or revolute joints and hinge joints with a fixed axis of rotation. The method does not require manual adjustment of any optimisation parameters and produces closed form solutions. It is a least squares solution using the whole 3D motion data set. We do not assume strict rigidity but only that the markers maintain a constant distance from the centre or axis of rotation. This method is compared with other methods that use similar assumptions in the cases of random measurement errors, systematic skin movements and skin movements with random measurement noise. Simulation results indicate that the new method is superior in terms of the algorithm used, the closure of the solution, consistency and minimal manual parameter adjustment. The method can also be adapted to joints with translational movements.

Entities:  

Mesh:

Year:  2002        PMID: 11747887     DOI: 10.1016/s0021-9290(01)00160-9

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  27 in total

1.  Full-Body Musculoskeletal Model for Muscle-Driven Simulation of Human Gait.

Authors:  Apoorva Rajagopal; Christopher L Dembia; Matthew S DeMers; Denny D Delp; Jennifer L Hicks; Scott L Delp
Journal:  IEEE Trans Biomed Eng       Date:  2016-07-07       Impact factor: 4.538

2.  3D inverse dynamics in non-orthonormal segment coordinate system.

Authors:  R Dumas; L Chèze
Journal:  Med Biol Eng Comput       Date:  2007-01-25       Impact factor: 2.602

3.  Knee functional flexion axis in osteoarthritic patients: comparison in vivo with transepicondylar axis using a navigation system.

Authors:  F Colle; S Bignozzi; N Lopomo; S Zaffagnini; L Sun; M Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-14       Impact factor: 4.342

4.  Proprioception in total, hemi- and reverse shoulder arthroplasty in 3D motion analyses: a prospective study.

Authors:  Philip Kasten; Michael Maier; Oliver Rettig; Patric Raiss; Sebastian Wolf; Markus Loew
Journal:  Int Orthop       Date:  2008-10-28       Impact factor: 3.075

5.  Robust identification of three-dimensional thumb and index finger kinematics with a minimal set of markers.

Authors:  Raviraj Nataraj; Zong-Ming Li
Journal:  J Biomech Eng       Date:  2013-09       Impact factor: 2.097

6.  How pigeons couple three-dimensional elbow and wrist motion to morph their wings.

Authors:  Amanda K Stowers; Laura Y Matloff; David Lentink
Journal:  J R Soc Interface       Date:  2017-08       Impact factor: 4.118

7.  Assessment of anatomical and reverse total shoulder arthroplasty with the scapula-weighted Constant-Murley score.

Authors:  Giovanni Merolla; Ilaria Parel; Andrea Giovanni Cutti; Maria Vittoria Filippi; Paolo Paladini; Giuseppe Porcellini
Journal:  Int Orthop       Date:  2018-08-10       Impact factor: 3.075

8.  Does total knee arthroplasty modify flexion axis of the knee?

Authors:  F Iacono; D Bruni; S Bignozzi; F Colle; M Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-15       Impact factor: 4.342

9.  Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis.

Authors:  Xavier Robert-Lachaine; Hakim Mecheri; Christian Larue; André Plamondon
Journal:  Med Biol Eng Comput       Date:  2016-07-05       Impact factor: 2.602

10.  Muscle contributions to fore-aft and vertical body mass center accelerations over a range of running speeds.

Authors:  Samuel R Hamner; Scott L Delp
Journal:  J Biomech       Date:  2012-12-11       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.