Literature DB >> 11747176

Measurement of radial artery spasm using an automatic pullback device.

F Kiemeneij1, B U Vajifdar, S C Eccleshall, G Laarman, T Slagboom, R van der Wieken.   

Abstract

Current evaluation of radial artery spasm (RAS), a frequent finding during the transradial approach for coronary angiography and angioplasty (TRA), is subjective. A quantitative measure of RAS will help in evaluation and comparison of management strategies. The objectives of the study were to assess the feasibility and safety of using an automatic pullback device (APD) for removal of transradial introducer sheaths and to establish a parameter to quantify RAS. In 50 consecutive transradial procedures, the APD was used to measure the force required for sheath removal. The mean maximal pullback force (MPF) was 0.53 +/- 0.52 kg (range, 0.1-3.0 kg). In 48 (96%) cases, the MPF was reached within the first 5 sec of pullback. All patients with clinical RAS (n = 4) had an MPF greater than 1.0 kg, while the remaining had an MPF less than 1.0 kg. All patients with severe pain during sheath removal (n = 3) had an MPF greater than 1.0 kg, while no patient with an MPF less than 1.0 kg had severe pain. It is feasible and safe to remove transradial introducer sheaths using the APD. The MPF is achieved within the first 5 sec of pullback and is a reliable parameter to quantify RAS. An MPF more than 1.0 kg correlates with clinical RAS and is associated with severe pain during sheath removal. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11747176     DOI: 10.1002/ccd.1307

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  4 in total

1.  Expert Opinion: Transradial Coronary Artery Procedures: Tips for Success.

Authors:  Kully Sandhu; Robert Butler; James Nolan
Journal:  Interv Cardiol       Date:  2017-05

2.  Need for prophylactic application of verapamil in transradial coronary procedures: a randomized trial. The VITRIOL (is Verapamil In TransRadial Interventions OmittabLe?) trial.

Authors:  Istvan Hizoh; Zsuzsanna Majoros; Laszlo Major; Zalan Gulyas; Gabor Szabo; Gabor Kerecsen; Andras Korda; Ferenc Molnar; Robert Gabor Kiss
Journal:  J Am Heart Assoc       Date:  2014-04-14       Impact factor: 5.501

3.  Propofol to relieve radial artery spasm.

Authors:  Monish Raut; R R Mantri; Manish Sharma; Arun Maheshwari
Journal:  Indian Heart J       Date:  2016-03-24

4.  Comparison of transradial coronary intervention for left main bifurcation disease using the new Braidin® slender 7 Fr sheath and a standard 6 Fr sheath.

Authors:  Yingkai Xu; Yingkai Li; Jiancai Yu; Deguang Wang; Qi Zhao; Yujing Cheng; Yujie Zhou
Journal:  J Int Med Res       Date:  2020-09       Impact factor: 1.671

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.