FAST sequences optimization for contrast media pharmacokinetic quantification in tissue.

M K Ivancevic1, I Zimine, F Lazeyras, D Foxall, J P Vallée.   

Abstract

The purpose of this study was to investigate the influence of the fast gradient-recalled echo (GRE) sequence parameters on the contrast dynamic range and signal sensitivity, to optimize the magnetic resonance (MR) sequence for contrast media pharmacokinetic assessment. Effects of the fast low-angle shot (FLASH), Fast acquisition at steady rate (FAST), and radiofrequency-spoiled (RF)-FAST sequence parameters were studied in vitro. The FAST sequence had the highest sensitivity in low gadolinium (Gd) concentration. The FLASH and RF-FAST sequences had a larger contrast dynamic range, but the FLASH images contained side band artifacts. Increasing the flip angle to 90 degrees raised the sensitivity of the FAST sequence and the contrast dynamic range of the RF-FAST sequence. The shortest possible TE was optimal for both contrast dynamics and imaging time. TI had an influence on the sensitivity of the FAST sequence only for small acquisition matrices. This study indicates the optimal parameters for contrast dynamics (RF-FAST, 90 degrees flip angle, shortest possible TE) and sensitivity (FAST, 90 degrees flip angle, long TI(eff)). Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11747035     DOI: 10.1002/jmri.10009

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Development and characterization of a dynamic lesion phantom for the quantitative evaluation of dynamic contrast-enhanced MRI.

Authors:  Melanie Freed; Jacco A de Zwart; Prasanna Hariharan; Matthew R Myers; Aldo Badano
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Comparison of myocardial perfusion estimates from dynamic contrast-enhanced magnetic resonance imaging with four quantitative analysis methods.

Authors:  Nathan A Pack; Edward V R DiBella
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

3.  Estimating myocardial perfusion from dynamic contrast-enhanced CMR with a model-independent deconvolution method.

Authors:  Nathan A Pack; Edward V R DiBella; Thomas C Rust; Dan J Kadrmas; Christopher J McGann; Regan Butterfield; Paul E Christian; John M Hoffman
Journal:  J Cardiovasc Magn Reson       Date:  2008-11-12       Impact factor: 5.364

Review 4.  Added Value of Assessing Adnexal Masses with Advanced MRI Techniques.

Authors:  I Thomassin-Naggara; D Balvay; A Rockall; M F Carette; M Ballester; E Darai; M Bazot
Journal:  Biomed Res Int       Date:  2015-08-27       Impact factor: 3.411