Literature DB >> 11746915

Determination of hydroxyalkyl derivatives of cobalamin (vitamin B12) using reversed phase high performance liquid chromatography with electrospray tandem mass spectrometry and ultraviolet diode array detection.

T Alsberg1, J Minten, J Haglund, M Törnqvist.   

Abstract

Electrospray ionization tandem mass spectrometry (ESI-MS/MS) and ultraviolet diode array detection (UV-DAD), coupled on-line to reversed phase high performance liquid chromatography (HPLC), was used for the characterization of hydroxyalkyl derivatives of cob(I)alamin. The reduced form of vitamin B12, cob(I)alamin, denoted a supernucleophile due to its high nucleophilic strength, has shown promise as an analytical tool in studies of electrophilically reactive compounds in vitro and in vivo. A method for analysis of DNA-phosphate adducts was developed earlier utilizing the supernucleophilicity of cob(I)alamin to transfer alkyl groups from the phosphotriester configuration in DNA, with the formation of a Co-substituted alkyl-cobalamin (alkyl-Cbl) complex. For the purpose of identification and quantification of alkyl-Cbls at high sensitivity, an MS/MS method has been developed with application to a number of 2-hydroxyalkyl-cobalamins (OHalkyl-Cbls). The precursor oxiranes were reacted with cob(I)alamin, followed by clean-up and mass spectrometric analysis of the resulting OHalkyl-Cbls. It was found that ionization was highly dependent on solvent composition. By using acetonitrile/water/trifluoroacetic acid (TFA) (eluent I), the base peak was the doubly protonated molecule [M + 2H](2+), whereas acetonitrile/water/1-methylpiperidine (eluent II) yielded the singly protonated molecule [M + H](+) as the base peak. Excellent separation was obtained with eluent II, with good separation between stereoisomers, thus enabling the characterization of these by means of UV spectra. Limits of quantitation for 2-hydroxypropyl-cobalamin (OHPr-Cbl) were 0.2 and 2 pg/microL (or 0.1 and 1 fmol/microL) using selected ion recording (SIR) with eluent I and II, respectively. The obtained detection level should be sufficient for analysis of alkyl-Cbls from a wide range of toxicological applications. Copyright 2001 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11746915     DOI: 10.1002/rcm.527

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  1 in total

1.  Identification and quantitation of cobalamin and cobalamin analogues in human feces.

Authors:  Robert H Allen; Sally P Stabler
Journal:  Am J Clin Nutr       Date:  2008-05       Impact factor: 7.045

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.