Literature DB >> 11745509

Optimized intensity-modulated arc therapy for prostate cancer treatment.

L Ma1, C X Yu, M Earl, T Holmes, M Sarfaraz, X A Li, D Shepard, P Amin, S DiBiase, M Suntharalingam, C Mansfield.   

Abstract

We recently implemented intensity-modulated arc therapy (IMAT) at our institution. In this study, we evaluate the dosimetric merits of the application of this technique to the treatment of prostate cancer. Each IMAT treatment plan incorporated bilateral overlapping arcs. The dose from each beam segment was computed using the three-dimensional dose model of a clinical treatment planning system (Render Plan 3.5, Precision Therapy). The weights assigned to the individual arc segments were optimized using a gradient search method. For 12 patients, comparisons were made between the IMAT treatment plans and corresponding plans using fixed cone-beam intensity-modulated radiotherapy (IMRT) from a commercial inverse planning system (CORVUS, NOMOS Corp.). We found that the optimized IMAT treatments produced similar dose distributions to the IMRT deliveries. Compared with the IMRT treatments, the IMAT treatments produced slightly less target dose homogeneity with consistently greater sparing of the rectum in regions of lower dose. The trade-off between target dose conformity and rectum sparing can be adjusted in both optimization procedures. Because the total beam-on time for IMAT delivery is 1 to 2 minutes with approximately 5-6 minutes of patient setup time, the delivery efficiency of the IMAT treatment was significantly better than the multiple-beam IMRT treatment. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11745509     DOI: 10.1002/ijc.1039

Source DB:  PubMed          Journal:  Int J Cancer        ISSN: 0020-7136            Impact factor:   7.396


  9 in total

Review 1.  Radiation medicine innovations for the new millenium.

Authors:  Dwight E Heron; Karen D Godette; Ray A Wynn; V Elayne Arterbery; Oscar A Streeter; Mack Roach; Joseph R Simpson; Melissa Blough; Charles R Thomas
Journal:  J Natl Med Assoc       Date:  2003-01       Impact factor: 1.798

2.  Radiotherapy treatment of early-stage prostate cancer with IMRT and protons: a treatment planning comparison.

Authors:  Alexei Trofimov; Paul L Nguyen; John J Coen; Karen P Doppke; Robert J Schneider; Judith A Adams; Thomas R Bortfeld; Anthony L Zietman; Thomas F Delaney; William U Shipley
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-05-21       Impact factor: 7.038

3.  Quality Control of Portal Imaging with PTW EPID QC PHANTOM.

Authors:  Csilla Pesznyák; Gábor Fekete; Arpád Mózes; Balázs Kiss; Réka Király; István Polgár; Pál Zaránd; Arpád Mayer
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

4.  Quasi-IMAT technique and secondary cancer risk in prostate cancer.

Authors:  Judith Alvarez Moret; Oliver Koelbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2009-04-16       Impact factor: 3.621

5.  Assessment of the robustness of volumetric-modulated arc therapy for lung radiotherapy.

Authors:  K Edmunds; J Bedford
Journal:  Br J Radiol       Date:  2013-02-07       Impact factor: 3.039

6.  Two-step intensity modulated arc therapy (2-step IMAT) with segment weight and width optimization.

Authors:  Jidi Sun; Theam Yong Chew; Juergen Meyer
Journal:  Radiat Oncol       Date:  2011-06-02       Impact factor: 3.481

7.  Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom.

Authors:  Masao Tanooka; Hiroshi Doi; Hideharu Miura; Hiroyuki Inoue; Yasue Niwa; Yasuhiro Takada; Masayuki Fujiwara; Toshiyuki Sakai; Kiyoshi Sakamoto; Norihiko Kamikonya; Shozo Hirota
Journal:  J Radiat Res       Date:  2013-05-17       Impact factor: 2.724

8.  Treatments of exceptionally large prostate cancer patients with low-energy intensity-modulated photons.

Authors:  Mei Sun; Lijun Ma
Journal:  J Appl Clin Med Phys       Date:  2006-11-28       Impact factor: 2.102

9.  Evaluation of the sensitivity of two 3D diode array dosimetry systems to setup error for quality assurance (QA) of volumetric-modulated arc therapy (VMAT).

Authors:  Guangjun Li; Sen Bai; Nianyong Chen; Lansdale Henderson; Kui Wu; Jianghong Xiao; Yingjie Zhang; Qingfeng Jiang; Xiaoqin Jiang
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.