Literature DB >> 11744415

Postoperative course of S-100B protein and neuron-specific enolase in patients after implantation of continuous and pulsatile flow LVADs.

E V Potapov1, M Loebe, H Abdul-Khaliq, A Koster, J Stein, R Sodian, M Kopitz, H Hausmann, G P Noon, M E DeBakey, R Hetzer.   

Abstract

BACKGROUND: In the early post-operative period after implantation of a continuous flow left ventricular assist device (LVAD) a non-pulsatile flow occurs. We compared the post-operative time-courses of protein S-100B (S100B) and neuron-specific enolase (NSE) as biochemical markers of brain injury in patients after implantation of a continuous flow LVAD and patients receiving a pulsatile flow LVAD.
METHODS: Since 1998 the continuous flow DeBakey VAD has been implanted in 8 patients at our institution. For comparison purposes, a group of 7 consecutive patients in whom a pulsatile Novacor N100 LVAD was implanted were investigated. In both groups cardiopulmonary bypass (CPB) with cardiotomy suction was used. S100B and NSE were measured in serum pre-operatively, 4 hours after CPB, and on days 1, 3, 7, and 14 after implantation of the LVAD. A neurologic examination was performed pre-operatively and post-operatively on days 3 and 14.
RESULTS: No differences were found between groups in pre-operative characteristics. The analysis of variance with repeated measurements for S-100B and NSE showed significant time effects (p = 0.004, p = 0.009, respectively) but no group effects (p = 0.06, p = 0.26, respectively) and no interaction between groups and time (p = 0.12, p = 0.48, respectively). The pre-operative serum level of S100B was significantly higher (p = 0.03) in the DeBakey VAD group. The pre-operative serum level of NSE was similar in the 2 groups (p = 0.7). In both groups there was a significant increase of S100B and NSE immediately after surgery (S100B: p = 0.006, p = 0.019; NSE: p = 0.01, p = 0.001). The values returned to pre-operative levels in the DeBakey VAD group on day 1 after implantation and in the Novacor group for S100B on day 3 and NSE on day 1. Post-operatively the mean values of S100B and NSE in the DeBakey VAD group compared with the Novacor group were significantly elevated only on day 3 (p = 0.005, p = 0.023).No neurologic complications were noted in patients with a continuous flow LVAD, whereas in the pulsatile LVAD group 2 patients presented neurologic abnormalities during the study period.
CONCLUSIONS: The similar course of biochemical markers of brain damage in both groups may indicate that the non-pulsatile flow in the early post-operative period does not lead to increased brain injury or permeability of the brain blood barrier.Elevated levels of S100B and NSE in the post-operative period can be used as diagnostic markers of brain injury in patients after implantation of both types of LVAD.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11744415     DOI: 10.1016/s1053-2498(01)00351-5

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  5 in total

1.  Alteration of LV end-diastolic volume by controlling the power of the continuous-flow LVAD, so it is synchronized with cardiac beat: development of a native heart load control system (NHLCS).

Authors:  Akihide Umeki; Takashi Nishimura; Masahiko Ando; Yoshiaki Takewa; Kenji Yamazaki; Shunei Kyo; Minoru Ono; Tomonori Tsukiya; Toshihide Mizuno; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2011-11-12       Impact factor: 1.731

Review 2.  Physiological impact of continuous flow on end-organ function: clinical implications in the current era of left ventricular assist devices.

Authors:  Arvind Bhimaraj; Cesar Uribe; Erick E Suarez
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Jan-Mar

3.  Mood disorders are glial disorders: evidence from in vivo studies.

Authors:  Matthias L Schroeter; Hashim Abdul-Khaliq; Julia Sacher; Johann Steiner; Ingolf E Blasig; Karsten Mueller
Journal:  Cardiovasc Psychiatry Neurol       Date:  2010-05-27

Review 4.  Physiologic effects of continuous-flow left ventricular assist devices.

Authors:  Aaron H Healy; Stephen H McKellar; Stavros G Drakos; Antigoni Koliopoulou; Josef Stehlik; Craig H Selzman
Journal:  J Surg Res       Date:  2016-01-20       Impact factor: 2.192

Review 5.  Serum S100B represents a new biomarker for mood disorders.

Authors:  Matthias L Schroeter; Julia Sacher; Johann Steiner; Peter Schoenknecht; Karsten Mueller
Journal:  Curr Drug Targets       Date:  2013-10       Impact factor: 3.465

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.