Literature DB >> 11743566

Comparison of color-flow Doppler scanning, power Doppler scanning, and frequency shift for assessment of carotid artery stenosis.

M Müller1, P Ciccotti, W Reiche, T Hagen.   

Abstract

OBJECTIVE: We investigated the accuracy of color-flow Doppler (CD) scanning, power Doppler (PD) scanning, and peak systolic Doppler frequency shift (PSF) in assessment of carotid artery stenosis with angiography used as gold standard, including the measurement techniques used in the North American Symptomatic Carotid Surgery Trial (NASCET) and the European Carotid Surgery Trial (ECST).
METHODS: Fifty-eight consecutive patients diagnosed for carotid artery surgery underwent color-coded duplex sonography and angiography. The duplex examination included the assessment of PSF and the videotaping of sagittal images in CD and PD mode from the proximal common carotid artery to the distal internal carotid artery. Two experienced examiners performed the studies, but once one examiner had done the taping, the other examiner was allowed only to review the tape. Separately, each examiner reviewed the tapes and determined by cursor settings each stenosis according to NASCET and ECST. For interobserver agreement kappa statistic was used. To compare with angiography (degree of stenosis 40%, 50%, 60%, 70%, and 80%) sensitivity, specificity, positive and negative predictive values, and overall accuracy were calculated. PSF cut-off frequencies were based on receiver operator curve analysis.
RESULTS: Because interobserver agreement in CD and PD was good (chance-corrected kappa > 0.6), further analysis used the between-observer mean value for each stenosis. With the NASCET measurement technique, accuracy of Doppler techniques to distinguish a 50% stenosis was 89% for PSF, 91% for CD, and 93% for PD; for a 70% stenosis it was 83% for PSF, 84% for CD, and 81% for PD. With the ECST measurement technique, accuracy to distinguish a 70% stenosis was 86% for PSF, 88% for CD, and 86% for PD; for an 80% stenosis it was 87% for PSF, 87% for CD, and 77% for PD.
CONCLUSION: CD and PD carotid artery stenosis measurements are highly reproducible, and in our hands provided accuracy equal to PSF.

Entities:  

Mesh:

Year:  2001        PMID: 11743566     DOI: 10.1067/mva.2001.118581

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  8 in total

1.  Correlation between carotid bifurcation calcium burden on non-enhanced CT and percentage stenosis, as confirmed by digital subtraction angiography.

Authors:  B Sarikaya; B Lohman; A M McKinney; S Gadani; M Irfan; L Lucato
Journal:  Br J Radiol       Date:  2011-09-06       Impact factor: 3.039

2.  Prevalence of findings compatible with carotid artery calcifications on dental panoramic radiographs.

Authors:  Stefan Bayer; Ernst-Heinrich Helfgen; Carolin Bös; Dominik Kraus; Norbert Enkling; Sebastian Mues
Journal:  Clin Oral Investig       Date:  2010-04-30       Impact factor: 3.573

3.  Carotid bifurcation calcium and correlation with percent stenosis of the internal carotid artery on CT angiography.

Authors:  Alexander M McKinney; Sean O Casey; Mehmet Teksam; Leandro T Lucato; Maurice Smith; Charles L Truwit; Stephen Kieffer
Journal:  Neuroradiology       Date:  2005-01-14       Impact factor: 2.804

4.  Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow.

Authors:  E M Jung; R Kubale; G Ritter; M T Gallegos; K-P Jungius; N Rupp; D-A Clevert
Journal:  Eur Radiol       Date:  2006-05-16       Impact factor: 5.315

5.  Wavelet-based neural network analysis of internal carotid arterial Doppler signals.

Authors:  Elif Derya Ubeyli; Inan Güler
Journal:  J Med Syst       Date:  2006-06       Impact factor: 4.460

6.  A classification system for stenosis from mitral valve Doppler signals using adaptive network based fuzzy inference system.

Authors:  Mahmut Tokmakçi
Journal:  J Med Syst       Date:  2007-10       Impact factor: 4.460

7.  Usage of a novel, similarity-based weighting method to diagnose atherosclerosis from carotid artery Doppler signals.

Authors:  Kemal Polat; Fatma Latifoğlu; Sadik Kara; Salih Güneş
Journal:  Med Biol Eng Comput       Date:  2007-10-25       Impact factor: 2.602

8.  Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography.

Authors:  D-A Clevert; T Johnson; E M Jung; D-A Clevert; P M Flach; T I Strautz; G Ritter; M T Gallegos; R Kubale; C Becker; M Reiser
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 7.034

  8 in total