Literature DB >> 11742961

Predicting success in weaning from mechanical ventilation.

M Meade1, G Guyatt, D Cook, L Griffith, T Sinuff, C Kergl, J Mancebo, A Esteban, S Epstein.   

Abstract

We identified 65 observational studies of weaning predictors that had been reported in 70 publications. After grouping predictors with similar names but different thresholds, the following predictors met our relevance criteria: heterogeneous populations, 51; COPD patients, 21; and cardiovascular ICU patients, 45. Many variables were of no use in predicting the results of weaning. Moreover, few variables had been studied in > 50 patients or had results presented to generate estimates of predictive power. For stepwise reductions in mechanical support, the most promising predictors were a rapid shallow breathing index (RSBI) < 65 breaths/min/L (measured using the ventilator settings that were in effect at the time that the prediction was made) and a pressure time product < 275 cm H2O/L/s. The pooled likelihood ratios (LRs) were 1.1 (95% confidence interval [CI], 0.95 to 1.28) for a respiratory rate [RR] of < 38 breaths/min and 0.32 (95% CI, 0.06 to 1.71) for an RR of > 38 breaths/min, which indicate that an RR of < 38 breaths/min leaves the probability of successful weaning virtually unchanged but that a value of > 38 breaths/min leads to a small reduction in the probability of success in weaning the level of mechanical support. For trials of unassisted breathing, the most promising weaning predictors include the following: RR; RSBI; a product of RSBI and occlusion pressure < 450 cm H2O breaths/min/L; maximal inspiratory pressure (PImax) < 20 cm H2O; and a knowledge-based system for adjusting pressure support. Pooled results for the power of a positive test result for both RR and RSBI were limited (highest LR, 2.23), while the power of a negative test result was substantial (ie, LR, 0.09 to 0.23). Summary data suggest a similar predictive power for RR and RSBI. In the prediction of successful extubation, an RR of < 38 breaths/min (sensitivity, 88%; specificity, 47%), an RSBI < 100 or 105 breaths/min/L (sensitivity, 65 to 96%; specificity, 0 to 73%), PImax, and APACHE (acute physiology and chronic health evaluation) II scores that are obtained at hospital admission appear to be the most promising. After pooling, two variables appeared to have some value. An RR of > 38 breaths/min and an RSBI of > 100 breaths/min/L appear to reduce the probability of successful extubation, and PImax < 0.3, for which the pooled LR is 2.23 (95% CI, 1.15 to 4.34), appears to marginally increase the likelihood of successful extubation. Judging by areas under the receiver operator curve for all variables, none of these variables demonstrate more than modest accuracy in predicting weaning outcome. Why do most of these tests perform so poorly? The likely explanation is that clinicians have already considered the results when they choose patients for trials of weaning.

Entities:  

Mesh:

Year:  2001        PMID: 11742961     DOI: 10.1378/chest.120.6_suppl.400s

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  57 in total

1.  Putting it all together to predict extubation outcome.

Authors:  Scott K Epstein
Journal:  Intensive Care Med       Date:  2004-05-25       Impact factor: 17.440

2.  A novel fuzzy logic inference system for decision support in weaning from mechanical ventilation.

Authors:  Yusuf Alper Kilic; Ilke Kilic
Journal:  J Med Syst       Date:  2009-06-11       Impact factor: 4.460

Review 3.  Variable performance of weaning-predictor tests: role of Bayes' theorem and spectrum and test-referral bias.

Authors:  Martin J Tobin; Amal Jubran
Journal:  Intensive Care Med       Date:  2006-11-08       Impact factor: 17.440

4.  Evolution of pattern of breathing during a spontaneous breathing trial predicts successful extubation.

Authors:  Leopoldo N Segal; Erwin Oei; Beno W Oppenheimer; Roberta M Goldring; Rami T Bustami; Salvatore Ruggiero; Kenneth I Berger; Stanley B Fiel
Journal:  Intensive Care Med       Date:  2009-11-28       Impact factor: 17.440

Review 5.  Acute lung failure.

Authors:  Rob Mac Sweeney; Daniel F McAuley; Michael A Matthay
Journal:  Semin Respir Crit Care Med       Date:  2011-10-11       Impact factor: 3.119

Review 6.  The critically ill asthmatic--from ICU to discharge.

Authors:  Samuel Louie; Brian M Morrissey; Nicholas J Kenyon; Timothy E Albertson; Mark Avdalovic
Journal:  Clin Rev Allergy Immunol       Date:  2012-08       Impact factor: 8.667

7.  Plasma Concentrations of Soluble Suppression of Tumorigenicity-2 and Interleukin-6 Are Predictive of Successful Liberation From Mechanical Ventilation in Patients With the Acute Respiratory Distress Syndrome.

Authors:  Jehan W Alladina; Sean D Levy; Kathryn A Hibbert; James L Januzzi; R Scott Harris; Michael A Matthay; B Taylor Thompson; Ednan K Bajwa
Journal:  Crit Care Med       Date:  2016-09       Impact factor: 7.598

8.  Extubation failure in intensive care unit: predictors and management.

Authors:  Atul P Kulkarni; Vandana Agarwal
Journal:  Indian J Crit Care Med       Date:  2008-01

9.  Routine use of weaning predictors: not so fast.

Authors:  Scott K Epstein
Journal:  Crit Care       Date:  2009-10-21       Impact factor: 9.097

10.  A new integrative weaning index of discontinuation from mechanical ventilation.

Authors:  Sergio N Nemer; Carmen S V Barbas; Jefferson B Caldeira; Thiago C Cárias; Ricardo G Santos; Luiz C Almeida; Leandro M Azeredo; Rosângela A Noé; Bruno S Guimarães; Paulo C Souza
Journal:  Crit Care       Date:  2009-09-22       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.