Literature DB >> 11742651

Comparison of commercial assays for the quantification of HBV DNA load in health care workers: calibration differences.

N Gilbert1, S Corden, S Ijaz, P R Grant, R S Tedder, E H Boxall.   

Abstract

Until recently, carriers of hepatitis B virus (HBV) were allowed to undertake exposure prone procedures providing their serum did not contain HBeAg. However, the recent description of hepatitis B transmission events occurring from HBV-infected health care workers who conduct exposure prone procedures demonstrated that the then current Department of Health guidelines needed to be revised. As part of a series of studies carried out to determine if viral load measurements are a more secure means of assessing the conduct of exposure prone procedures, the suitability of commercially available assays for HBV DNA detection and quantification were investigated. This study describes a comparative analysis on the performances of three assays each based on a different methodology. The assays included the QUANTIPLEX HBV DNA Assay (bDNA), (Chiron Diagnostics Ltd.), the AMPLICOR HBV Monitor Test, (Roche Diagnostics Systems) and the Digene Hybrid Capture System HBV DNA Assay (Digene Corporation). Calibration curves from experiments using the Eurohep ad and ay HBV DNA standard controls indicated a close correlation between the three assays over the dynamic ranges claimed by the manufacturers, although the Quantiplex assay did appear to be over-reporting. This became more apparent when testing patients undergoing anti-viral therapy where the Quantiplex assay consistently over-reported by 0.5 log(10) when compared with the Amplicor assay. The results of this study indicate that based on its dynamic range, the Amplicor HBV Monitor test is the most appropriate assay for the routine investigation of anti-HBe carriers, which will have lower levels of HBV DNA. The investigation also highlights the need for using accepted standard HBV DNA control sera. This will be essential when using an assay to establish whether health care workers who are hepatitis B carriers can be allowed to perform exposure prone procedures under the new guidelines of the UK Department of Health.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11742651     DOI: 10.1016/s0166-0934(01)00396-2

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  6 in total

1.  Occult hepatitis B virus infection in Lebanese patients with chronic hepatitis C liver disease.

Authors:  S Ramia; A I Sharara; M El-Zaatari; F Ramlawi; Z Mahfoud
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2008-03       Impact factor: 3.267

Review 2.  Epidemiology of hepatitis C virus infection.

Authors:  Miriam J Alter
Journal:  World J Gastroenterol       Date:  2007-05-07       Impact factor: 5.742

3.  Clinical evaluation of the COBAS Amplicor HBV monitor test for measuring serum HBV DNA and comparison with the Quantiplex branched DNA signal amplification assay in Taiwan.

Authors:  C-Y Dai; M-L Yu; S-C Chen; Z-Y Lin; M-Y Hsieh; L-Y Wang; J-F Tsai; W-L Chuang; W-Y Chang
Journal:  J Clin Pathol       Date:  2004-02       Impact factor: 3.411

4.  Establishment and assessment of two methods for quantitative detection of serum duck hepatitis B virus DNA.

Authors:  Ya-Xi Chen; Ai-Long Huang; Zhen-Yuan Qi; Shu-Hua Guo
Journal:  World J Gastroenterol       Date:  2004-09-15       Impact factor: 5.742

Review 5.  Quantitative nucleic acid amplification methods and their implications in clinical virology.

Authors:  Mini P Singh; Shipra Galhotra; Karnika Saigal; Archit Kumar; Radha Kanta Ratho
Journal:  Int J Appl Basic Med Res       Date:  2017 Jan-Mar

6.  Nanosensor dosimetry of mouse blood proteins after exposure to ionizing radiation.

Authors:  Dokyoon Kim; Francesco Marchetti; Zuxiong Chen; Sasa Zaric; Robert J Wilson; Drew A Hall; Richard S Gaster; Jung-Rok Lee; Junyi Wang; Sebastian J Osterfeld; Heng Yu; Robert M White; William F Blakely; Leif E Peterson; Sandhya Bhatnagar; Brandon Mannion; Serena Tseng; Kristen Roth; Matthew Coleman; Antoine M Snijders; Andrew J Wyrobek; Shan X Wang
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.