Literature DB >> 11742311

Effects of recycling on the mechanical properties and the surface topography of nickel-titanium alloy wires.

S H Lee1, Y I Chang.   

Abstract

The purpose of this study was to investigate the changes in mechanical properties, surface topography, and frictional forces of various nickel-titanium wires after recycling. Three types of nickel-titanium wires were separated into 3 groups: as-received condition (T0, control group), treated in artificial saliva for 4 weeks (T1), and treated in artificial saliva and autoclaved (T2). Strength changes were observed by tensile testing, and surface topography was assessed by scanning electron microscope and 3-D profilogram. Frictional coefficients were tested by friction test, and fatigue by bending fatigue test. Our findings showed that there were no statistically significant differences between the wires in maximum tensile strength, elongation rate, modulus of elasticity, and bending fatigue. Two wires demonstrated increased pitting and corrosion after recycling. The same 2 wires also demonstrated significantly greater surface roughness and maximum frictional coefficients compared with the control wires (P <.05), but the third wire showed no significant difference. However, surface roughness and frictional coefficient of the 2 wires after recycling were not greater than those of the third wire before treatment. Recycling increased the surface roughness and friction coefficients, but these seemed to have limited clinical significance.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11742311     DOI: 10.1067/mod.2001.118997

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  7 in total

1.  Effects of Er:YAG laser treatments on surface roughness of base metal alloys.

Authors:  Göknil Ergün Kunt; Ahmet Umut Güler; Gözlem Ceylan; Ibrahim Duran; Pelin Ozkan; Tuğrul Kirtiloğlu
Journal:  Lasers Med Sci       Date:  2010-10-20       Impact factor: 3.161

2.  Evaluation of Mechanical and Physical Properties of Clinically Used and Recycled Superelastic NiTi Wires.

Authors:  Venkata Naidu Bavikati; Gowri Sankar Singaraju; Prasad Mandava; Sai Sandeep Killamsetty; Venkatesh Nettam; Praveen Kumar Reddy Karnati
Journal:  J Clin Diagn Res       Date:  2016-07-01

3.  Effect of immersion in hydrochloric acid and sodium hypochlorite and autoclave sterilization on the force characteristics of orthodontic nickel-titanium open coils.

Authors:  Saeed Noorollahian; Mehrnaz Zakizade
Journal:  Dent Res J (Isfahan)       Date:  2021-02-23

4.  In-vitro evaluation of the effects of insertion and sterilization procedures on the mechanical and surface characteristics of mini screws.

Authors:  Civan Aved Hergel; Yasemin Bahar Acar; Mustafa Ates; Nazan Kucukkeles
Journal:  Eur Oral Res       Date:  2019-01-01

5.  Evaluation of the Effect of Different Types of Fluoride on Tensile Properties and Surface Roughness of Different Titanium-Based Archwires: An In vivo Study.

Authors:  Rajkumar Balakrishnan; Sumaya Yousuf Jeri; V R Rekha; Gangesh Bahadur Singh; P R Deepak; Achuthan Nair
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10

6.  Effect of Recycling and Autoclave Sterilization on the Unloading Forces of NiTi Closed-Coil Springs: An In Vitro Study.

Authors:  Sh Momeni Danaei; M Oshagh; A Khozaei
Journal:  J Dent (Shiraz)       Date:  2013-12

7.  Evaluation of tensile strength and surface topography of orthodontic wires after infection control procedures: An in vitro study.

Authors:  M Brindha; N Kurunji Kumaran; K Rajasigamani
Journal:  J Pharm Bioallied Sci       Date:  2014-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.