A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.

H Sakoda1, A M Voice, H M McEwen, G H Isaac, C Hardaker, B M Wroblewski, J Fisher.   

Abstract

Cross-linked polyethylenes are being introduced widely in acetabular cups in hip prostheses as a strategy to reduce the incidence of wear debris-induced osteolysis. It will be many years before substantial clinical data can be collected on the wear of these new materials. Silane cross-linked polyethylene (XLPE) was introduced into clinical practice in a limited series of acetabular cups in 1986 articulating against 22.225-mm alumina ceramic femoral heads and showed reduced wear rates compared with conventionally sterilized (gamma irradiation in air) ultra-high molecular weight polyethylene (UHMWPE). We compared the wear of XLPE manufactured in 1986 with the wear of UHMWPE manufactured in 1986 in nonirradiated and irradiated forms. In the nonirradiated forms, the wear of XLPE was 3 times less than UHWMPE when articulating against smooth counterfaces. The nonirradiated materials did not show signs of oxidation. In the irradiated forms, only UHMWPE showed high levels of oxidation, and this caused a substantial increase in wear. Antioxidants added to XLPE during processing gave resistance to oxidative degradation. When sliding against scratched counterfaces, the wear of UHMWPE increased by a factor of 2 to 3 times. Against the same scratched counterfaces, the wear of XLPE increased dramatically by 30 to 200 times. This difference may be attributed to the reduction in toughness of XLPE. Clinically, XLPE has been articulated against damage-resistant ceramic heads, and this probably has been an important factor in contributing to reduced wear. New cross-linked polyethylenes differ considerably from XLPE. This study indicates that it is prudent to examine the wear of new polyethylenes under a range of conditions that may occur in vivo.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11740757     DOI: 10.1054/arth.2001.27234

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study.

Authors:  Zoran Bascarevic; Zoran Vukasinovic; Nemanja Slavkovic; Borislav Dulic; Goran Trajkovic; Violeta Bascarevic; Sladjan Timotijevic
Journal:  Int Orthop       Date:  2009-11-01       Impact factor: 3.075

2.  Scratching vulnerability of conventional vs highly cross-linked polyethylene liners because of large embedded third-body particles.

Authors:  Anneliese D Heiner; Alison L Galvin; John Fisher; John J Callaghan; Thomas D Brown
Journal:  J Arthroplasty       Date:  2011-11-23       Impact factor: 4.757

3.  The effects of peroxide content on the wear behavior, microstructure and mechanical properties of peroxide crosslinked ultra-high molecular weight polyethylene used in total hip replacement.

Authors:  Rizwan M Gul
Journal:  J Mater Sci Mater Med       Date:  2008-01-25       Impact factor: 3.896

Review 4.  Arthroplasty in Femoral Head Osteonecrosis.

Authors:  Yoon Je Cho; Dong Cheol Nam; Kwangyoung Jung
Journal:  Hip Pelvis       Date:  2014-06-30

Review 5.  Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints.

Authors:  Md J Nine; Dipankar Choudhury; Ay Ching Hee; Rajshree Mootanah; Noor Azuan Abu Osman
Journal:  Materials (Basel)       Date:  2014-02-10       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.