Literature DB >> 11740355

Bioactive bone cement as a principal fixture for spinal burst fracture: an in vitro biomechanical and morphologic study.

W W Lu1, K M Cheung, Y W Li, K D Luk, A D Holmes, Q A Zhu, J C Leong.   

Abstract

STUDY
DESIGN: An in vitro biomechanical and radiographic study to evaluate the properties of a newly developed bioactive bone cement for stabilization of the fractured spine, suitable for minimally invasive application.
OBJECTIVES: To determine the mechanical stability of the fractured spine after injection of the newly developed bioactive bone cement under quasi-static and cyclic loading regimens. SUMMARY OF BACKGROUND DATA: Bone cement injection has been reported as a potentially useful, minimally invasive technique for treating vertebral body fracture or stabilizing osteoporosis. However, potential problems associated with the use of polymethylmethacrylate (PMMA) have prompted the search for alternative solutions. The use of bioactive bone cement as a potential replacement for PMMA has been reported.
METHODS: Biomechanical and radiographic analyses were used to test the mechanical stability of the fractured spine. The cement used was formed from hydroxyapatite powder containing strontium and bisphenol A diglycidylether dimethacrylate (D-GMA) resin. Twenty-six fresh porcine spine specimens (T10-L1) were divided into three groups: pilot, intact, and cemented. Spinal stiffness and failure strength were recorded in the intact group with the specimens flexed at 10 degrees. Uniform injuries were created in all specimens of the cemented group, and compressive loading was applied with 10 degrees of flexion until a fracture occurred. The bone cement was injected into the fractured spine, and stiffness was evaluated after 1 hour. Failure strength was also recorded after 3000 and 20,000 fatigue load cycles. Morphology of the specimens was observed and evaluated.
RESULTS: Results from a cell biocompatibility test indicated that the new bioactive bone cement was favorable for cell growth. Spinal stiffness significantly decreased after fracture (47.5% of intact condition). Instant stiffness of the spine recovered to 107.8% of the intact condition after bone cement injection. After 3000 and 20,000 cycles of fatigue loading, stiffness of the cemented spine was found to be 93.5% and 94.4% of intact stiffness, respectively (P < 0.05). Average failure strength of the spine was 5056 N (after 3000 cycles) and 5301 N (after 20,000 cycles) after bone cement injection and fatigue loading. Radiographs and cross-sectional observations indicated a good cement-bone bonding and fracture fill.
CONCLUSIONS: A new bioactive bone cement without cytotoxic effect has been developed. Results show that minimally invasive techniques to apply this cement to porcine spines results in augmentation of mild burst fractures such that the original stiffness and strength of the vertebra are recovered. This new cement therefore shows potential as an augmentation to traditional instrumentation in the surgical management of vertebral fractures. The potential for further clinical applications is currently under investigation.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11740355     DOI: 10.1097/00007632-200112150-00010

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  13 in total

1.  Thoraco-lumbar traumatic vertebral fractures augmentation by osteo-conductive and osteo-inductive bone substitute containing strontium-hydroxyapatite: our experience.

Authors:  Salvatore Masala; Amedeo Taglieri; Antonio Chiaravalloti; Eros Calabria; Marco Morini; Riccardo Iundusi; Umberto Tarantino; Giovanni Simonetti
Journal:  Neuroradiology       Date:  2014-03-21       Impact factor: 2.804

2.  [Biocompatibility of polymer-bioglass cement Cortoss®: in vitro test with the MG63 cell model].

Authors:  C Fölsch; R Pinkernell; R Stiletto
Journal:  Orthopade       Date:  2013-03       Impact factor: 1.087

3.  Effects of cement augmentation on the mechanical stability of multilevel spine after vertebral compression fracture.

Authors:  Eelin Tan; Tian Wang; Matthew H Pelletier; William R Walsh
Journal:  J Spine Surg       Date:  2016-06

4.  Experimental and computational approach investigating burst fracture augmentation using PMMA and calcium phosphate cements.

Authors:  Sami M Tarsuslugil; Rochelle M O'Hara; Nicholas J Dunne; Fraser J Buchanan; John F Orr; David C Barton; Ruth K Wilcox
Journal:  Ann Biomed Eng       Date:  2014-01-07       Impact factor: 3.934

5.  Biomechanical evaluation of combined short segment fixation and augmentation of incomplete osteoporotic burst fractures.

Authors:  René Hartensuer; Dominic Gehweiler; Martin Schulze; Lars Matuszewski; Michael J Raschke; Thomas Vordemvenne
Journal:  BMC Musculoskelet Disord       Date:  2013-12-21       Impact factor: 2.362

6.  Therapeutic effects analysis of percutaneous kyphoplasty for osteoporotic vertebral compression fractures: A multicentre study.

Authors:  Huilin Yang; Liang Chen; Zhaomin Zheng; Guoyong Yin; William W Lu; Genlin Wang; Xuesong Zhu; Dechun Geng; Jun Zhou; Bin Meng; Haiqing Mao; Tao Liu; Junjie Niu; Tiansi Tang; Jun Zou
Journal:  J Orthop Translat       Date:  2017-05-15       Impact factor: 5.191

7.  Strontium enhances osseointegration of calcium phosphate cement: a histomorphometric pilot study in ovariectomized rats.

Authors:  Martin Baier; Patric Staudt; Roman Klein; Ulrike Sommer; Robert Wenz; Ingo Grafe; Peter Jürgen Meeder; Peter P Nawroth; Christian Kasperk
Journal:  J Orthop Surg Res       Date:  2013-06-07       Impact factor: 2.359

8.  Traumatic burst fracture with spinal channel involvement augmentation with bioactive strontium-hydroxyapatite cement.

Authors:  S Masala; E Calabria; G Nano; R Iundusi; L Greco; R Di Trapano; U Tarantino; G Simonetti
Journal:  Case Rep Orthop       Date:  2013-08-01

9.  Stepwise resection of the posterior ligamentous complex for stability of a thoracolumbar compression fracture: An in vitro biomechanical investigation.

Authors:  Yao Li; Zhonghai Shen; Mingyu Huang; Xiangyang Wang
Journal:  Medicine (Baltimore)       Date:  2017-09       Impact factor: 1.889

10.  Long-Segmental Posterior Fusion Combined With Vertebroplasty and Wiring: Alternative Surgical Technique for Kummell's Disease With Neurologic Deficits-A Retrospective Case Series.

Authors:  Hyung-Youl Park; Ki-Won Kim; Ji-Hyun Ryu; S Tim Yoon; In-Hwa Baek; Tae-Yang Jang; Jun-Seok Lee
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-06-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.