Literature DB >> 11740208

Three-dimensional pulsatile flow simulation before and after endovascular coil embolization of a terminal cerebral aneurysm.

C Groden1, J Laudan, S Gatchell, H Zeumer.   

Abstract

The effect of different percentages of coil mesh in a cerebral aneurysm on the pulsatile flow and pressure in the parent vessel and aneurysm lumen was evaluated. Geometric data on a basilar tip aneurysm and vertebrobasilar arteries after subarachnoid hemorrhage was obtained by computer tomographic angiography. Intraarterial pressure was measured at four vertebrobasilar points before and after treatment with detachable coils. Pulsatile flow was documented by transcranial ultrasonography. A three-dimensional computer simulation was created using a commercial fluid dynamics solver for four aneurysm conditions: (1) before intervention; (2) with a 20% filling showing a complete cessation of the inflow through the aneurysm neck; (3) with a 12% filling showing an incomplete deceleration of inflow through the aneurysm neck, with a remaining flow around the embedded platinum coils; and (4) with a 12% filling and simulation of clotted aneurysm dome, which did not inhibit persisting flow phenomena. The relative pressure amplitudes neither increased nor decreased under the different simulated aneurysm filling conditions. Inserted platinum coils can immediately and decisively relieve the influx of pulsating blood and allow for initial clotting. To reach this effect, a volume density of 20% platinum coil mesh in the aneurysm neck is needed.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11740208     DOI: 10.1097/00004647-200112000-00011

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  19 in total

1.  Angiographic follow-up of vertebrobasilar artery aneurysms treated with detachable coils.

Authors:  C Groden; B Eckert; T Ries; E Neumaier Probst; T Kucinski; H Zeumer
Journal:  Neuroradiology       Date:  2003-06-17       Impact factor: 2.804

2.  Computational fluid dynamics of cerebral aneurysm coiling using high-resolution and high-energy synchrotron X-ray microtomography: comparison with the homogeneous porous medium approach.

Authors:  Michael R Levitt; Michael C Barbour; Sabine Rolland du Roscoat; Christian Geindreau; Venkat K Chivukula; Patrick M McGah; John D Nerva; Ryan P Morton; Louis J Kim; Alberto Aliseda
Journal:  J Neurointerv Surg       Date:  2016-07-12       Impact factor: 5.836

3.  In vitro study of near-wall flow in a cerebral aneurysm model with and without coils.

Authors:  L Goubergrits; B Thamsen; A Berthe; J Poethke; U Kertzscher; K Affeld; C Petz; H-C Hege; H Hoch; A Spuler
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-20       Impact factor: 3.825

4.  Development and validation of models for the investigation of blood clotting in idealized stenoses and cerebral aneurysms.

Authors:  Andrew Narracott; Stephen Smith; Patricia Lawford; Hao Liu; Ryutaro Himeno; Iain Wilkinson; Paul Griffiths; Rodney Hose
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

5.  Virtual treatment of basilar aneurysms using shape memory polymer foam.

Authors:  J M Ortega; J Hartman; J N Rodriguez; D J Maitland
Journal:  Ann Biomed Eng       Date:  2013-01-18       Impact factor: 3.934

6.  Hemodynamic Characteristics Regarding Recanalization of Completely Coiled Aneurysms: Computational Fluid Dynamic Analysis Using Virtual Models Comparison.

Authors:  Wonhyoung Park; Yunsun Song; Kye Jin Park; Hae-Won Koo; Kuhyun Yang; Dae Chul Suh
Journal:  Neurointervention       Date:  2016-03-03

7.  Hemodynamics of Cerebral Aneurysms.

Authors:  Daniel M Sforza; Christopher M Putman; Juan Raul Cebral
Journal:  Annu Rev Fluid Mech       Date:  2009-01-01       Impact factor: 18.511

8.  Computational fluid dynamics of blood flow in coil-embolized aneurysms: effect of packing density on flow stagnation in an idealized geometry.

Authors:  Tomohiro Otani; Masanori Nakamura; Toshiyuki Fujinaka; Masayuki Hirata; Junko Kuroda; Katsuhiko Shibano; Shigeo Wada
Journal:  Med Biol Eng Comput       Date:  2013-03-26       Impact factor: 2.602

9.  Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.

Authors:  Tomohiro Otani; Satoshi Ii; Tomoyoshi Shigematsu; Toshiyuki Fujinaka; Masayuki Hirata; Tomohiko Ozaki; Shigeo Wada
Journal:  Med Biol Eng Comput       Date:  2016-07-21       Impact factor: 2.602

10.  Post-treatment hemodynamics of a basilar aneurysm and bifurcation.

Authors:  J Ortega; J Hartman; J Rodriguez; D Maitland
Journal:  Ann Biomed Eng       Date:  2008-07-16       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.