Literature DB >> 11738905

Gonioscopic changes after implantation of a posterior chamber lens in phakic myopic eyes.

C Abela-Formanek1, A J Kruger, I Dejaco-Ruhswurm, S Pieh, C Skorpik.   

Abstract

PURPOSE: To evaluate the effects of posterior chamber implantation of phakic intraocular lenses on angle structures and the correlation with intraocular pressure (IOP).
SETTING: Department of Ophthalmology, University Hospital of Vienna, Vienna, Austria.
METHODS: A Staar implantable contact lens (ICL) was implanted in 20 white patients (34 eyes) with high myopia. The patients were followed for a mean of 2.3 years (range 0.8 to 6.0 years). Two subgroups were created: One had a follow-up of 2.4 to 6.0 years and the other, 0.8 to 2.3 years. The mean spherical power of the implanted ICL was -16.8 diopters (D) (range -9.0 to -21.0 D). The angle structures were examined by gonioscopy using the Spaeth technique, and optical pachymetry and IOP were measured in dilated and undilated pupils. Trabecular pigmentation was measured semiquantitatively. The ICL models included a few prototypes (6 eyes), the V2 model (10 eyes), the V3 model (6 eyes), and the V4 model (12 eyes).
RESULTS: The anterior chamber angle was between 11 and 20 degrees in 41% of eyes, between 21 and 30 degrees in 21%, larger than 30 degrees in 21%, and 10 degrees or smaller in 17%. An apparent iris root insertion was above Schwalbe's line in 6% of eyes, behind Schwalbe's line in 12%, at the scleral spur in 67%, and in a deep angle recess behind the scleral spur in 15%. The curvature of the iris was regular in 19 eyes and steep in 15 eyes. The mean pigmentation in all 4 quadrants was 1.3. (Grade 1 was defined as trace pigmentation.) The mean pachymetry from the endothelium to the ICL anterior surface was 2.7 mm and from the endothelium to the anterior surface of the crystalline lens, 3.2 mm. The mean IOP was 14.1 mm Hg in undilated pupils and 12.1 mm Hg in dilated pupils. There was no correlation between angle pigmentation and IOP.
CONCLUSION: Trace pigmentation in the trabecular meshwork was common after ICL implantation. However, there was no direct influence on IOP. Long-term follow-up is necessary to evaluate the effect and progress of trabecular pigmentation in eyes with an ICL.

Entities:  

Mesh:

Year:  2001        PMID: 11738905     DOI: 10.1016/s0886-3350(01)01229-9

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye.

Authors:  Kunitoshi Fujisawa; Kimiya Shimizu; Shigekazu Uga; Masanobu Suzuki; Koichi Nagano; Yuuki Murakami; Hiroko Goseki
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-04-25       Impact factor: 3.117

Review 2.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

3.  An interesting case of implantable contact lens.

Authors:  V K Mohindra; Savio Pereira
Journal:  Med J Armed Forces India       Date:  2013-06-21

4.  Comparison of clear lens extraction and collamer lens implantation in high myopia.

Authors:  Ahmed M Emarah; Mostafa A El-Helw; Hazem M Yassin
Journal:  Clin Ophthalmol       Date:  2010-05-14

5.  Recurrent occlusion of laser iridotomy sites after posterior chamber phakic IOL implantation.

Authors:  In Ki Park; Je Myung Lee; Yeoun Sook Chun
Journal:  Korean J Ophthalmol       Date:  2008-06

6.  Novel observations and potential applications using digital infrared iris imaging.

Authors:  Daniel K Roberts; Ana S Lukic; Yongyi Yang; Sayoko E Moroi; Jacob T Wilensky; Miles N Wernick
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2009 Mar-Apr

7.  Etiology and Management of Raised Intraocular Pressure following Posterior Chamber Phakic Intraocular Lens Implantation in Myopic Eyes.

Authors:  Sirisha Senthil; Nikhil S Choudhari; Pravin K Vaddavalli; Somasheila Murthy; Jagadesh C Reddy; Chandra S Garudadri
Journal:  PLoS One       Date:  2016-11-17       Impact factor: 3.240

8.  Comparison of Visian toric collamer lens and toric acrylic intraocular lens implantation for the treatment of myopia with astigmatism.

Authors:  Hatem Ammar; Mohamed Anbar; Marwa M Abdellah
Journal:  Clin Ophthalmol       Date:  2016-12-29

9.  Multicenter survey on implantable collamer lens dislocation.

Authors:  Takashi Kojima; Yoshihiro Kitazawa; Tomoaki Nakamura; Kazutaka Kamiya; Kazuo Ichikawa; Akihito Igarashi; Kimiya Shimizu
Journal:  PLoS One       Date:  2022-02-14       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.