Literature DB >> 11737545

A dual path programmable array microscope (PAM): simultaneous acquisition of conjugate and non-conjugate images.

R Heintzmann1, Q S Hanley, D Arndt-Jovin, T M Jovin.   

Abstract

A programmable array microscope (PAM) incorporates a spatial light modulator (SLM) placed in the primary image plane of a widefield microscope, where it is used to define patterns of illumination and/or detection. We describe the characteristics of a special type of PAM collecting two images simultaneously. The conjugate image (Ic) is formed by light originating from the object plane and returning along the optical path of the illumination light. The non-conjugate image (Inc) receives light from only those regions of the SLM that are not used for illuminating the sample. The dual-signal PAM provides much more time-efficient excitation than the confocal laser scanning microscope (CLSM) and greater utilization of the available emission light. It has superior noise characteristics in comparison to single-sided instruments. The axial responses of the system under a variety of conditions were measured and the behaviour of the novel Inc image characterized. As in systems in which only Ic images are collected (Nipkow-disc microscopes, and previously characterized PAMs), the axial response to thin fluorescent films showed a sharpening of the axial response as the unit cell of the repetitive patterns decreased in size. The dual-signal PAM can be adapted to a wide range of data analysis and collection strategies. We investigated systematically the effects of patterns and unit cell dimensions on the axial response. Sufficiently sparse patterns lead to an Ic image formed by the superposition of the many parallel beams, each of which is equivalent to the single scanning spot of a CLSM. The sectioning capabilities of the system, as given by its axial responses, were similar for a given scan pattern and for processed pseudorandom sequence (PRS) scans with the same size of the unit cell. For the PRS scans, optical sectioning was achieved by a subtraction of an Inc image or, alternatively, a scaled widefield image from the Ic image. Based on the comparative noise levels of the two methods, the non-conjugate subtraction was significantly superior. A point spread function for Ic and Inc was simulated and properties of the optical transfer functions (OTFs) were compared. Simulations of the OTF in non-conjugate imaging did not suffer from the missing cone problem, enabling a high quality deconvolution of the non-conjugate side alone. We also investigated the properties of images obtained by subjecting the Ic and Inc data to a combined maximum likelihood deconvolution.

Mesh:

Year:  2001        PMID: 11737545     DOI: 10.1046/j.1365-2818.2001.00945.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  11 in total

Review 1.  Optical sectioning microscopy with planar or structured illumination.

Authors:  Jerome Mertz
Journal:  Nat Methods       Date:  2011-09-29       Impact factor: 28.547

2.  Super-resolution two-photon microscopy via scanning patterned illumination.

Authors:  Ben E Urban; Ji Yi; Siyu Chen; Biqin Dong; Yongling Zhu; Steven H DeVries; Vadim Backman; Hao F Zhang
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2015-04-07

Review 3.  Development of new photon-counting detectors for single-molecule fluorescence microscopy.

Authors:  X Michalet; R A Colyer; G Scalia; A Ingargiola; R Lin; J E Millaud; S Weiss; Oswald H W Siegmund; Anton S Tremsin; John V Vallerga; A Cheng; M Levi; D Aharoni; K Arisaka; F Villa; F Guerrieri; F Panzeri; I Rech; A Gulinatti; F Zappa; M Ghioni; S Cova
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2012-12-24       Impact factor: 6.237

Review 4.  Single cell optical imaging and spectroscopy.

Authors:  Anthony S Stender; Kyle Marchuk; Chang Liu; Suzanne Sander; Matthew W Meyer; Emily A Smith; Bhanu Neupane; Gufeng Wang; Junjie Li; Ji-Xin Cheng; Bo Huang; Ning Fang
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

5.  Specific visualization of glioma cells in living low-grade tumor tissue.

Authors:  Sven R Kantelhardt; Wouter Caarls; Anthony H B de Vries; Guy M Hagen; Thomas M Jovin; Walter Schulz-Schaeffer; Veit Rohde; Alf Giese; Donna J Arndt-Jovin
Journal:  PLoS One       Date:  2010-06-30       Impact factor: 3.240

6.  Fluorescence recovery after photobleaching and photoconversion in multiple arbitrary regions of interest using a programmable array microscope.

Authors:  Guy M Hagen; Wouter Caarls; Keith A Lidke; Anthony H B De Vries; Cornelia Fritsch; B George Barisas; Donna J Arndt-Jovin; Thomas M Jovin
Journal:  Microsc Res Tech       Date:  2009-06       Impact factor: 2.769

7.  Silicon photon-counting avalanche diodes for single-molecule fluorescence spectroscopy.

Authors:  Xavier Michalet; Antonino Ingargiola; Ryan A Colyer; Giuseppe Scalia; Shimon Weiss; Piera Maccagnani; Angelo Gulinatti; Ivan Rech; Massimo Ghioni
Journal:  IEEE J Sel Top Quantum Electron       Date:  2014-11       Impact factor: 4.544

8.  Adaptive optics parallel near-confocal scanning ophthalmoscopy.

Authors:  Jing Lu; Boyu Gu; Xiaolin Wang; Yuhua Zhang
Journal:  Opt Lett       Date:  2016-08-15       Impact factor: 3.776

9.  Programmable illumination and high-speed, multi-wavelength, confocal microscopy using a digital micromirror.

Authors:  Franck P Martial; Nicholas A Hartell
Journal:  PLoS One       Date:  2012-08-24       Impact factor: 3.240

10.  High-throughput FCS using an LCOS spatial light modulator and an 8 × 1 SPAD array.

Authors:  Ryan A Colyer; Giuseppe Scalia; Ivan Rech; Angelo Gulinatti; Massimo Ghioni; Sergio Cova; Shimon Weiss; Xavier Michalet
Journal:  Biomed Opt Express       Date:  2010-11-15       Impact factor: 3.732