Literature DB >> 11736776

The effect of posture on cerebral oxygenation during abdominal surgery.

G R Harrison1.   

Abstract

Performing surgery with a patient in the head-down position for several hours may cause marked facial and conjunctival oedema. It is not known whether oedema might also be occurring within the cranial cavity. This study, using near-infrared regional cerebral oximetry, was performed to see if there was any evidence of cerebral anoxia during operations performed with patients in the head-down position compared with those performed on patients who were flat. Patients managed in the head-down position did not demonstrate any reduction in regional cerebral oxygenation, but those who were managed flat did. An explanation of these paradoxical findings is elusive.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11736776     DOI: 10.1046/j.1365-2044.2001.02084.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  6 in total

1.  Can an airway assessment score predict difficulty at intubation in the emergency department?

Authors:  M J Reed; M J G Dunn; D W McKeown
Journal:  Emerg Med J       Date:  2005-02       Impact factor: 2.740

2.  The effects of sevoflurane and propofol anesthesia on cerebral oxygenation in gynecological laparoscopic surgery.

Authors:  Sung-Jin Kim; Jae Young Kwon; Ah-Reum Cho; Hae Kyu Kim; Tae Kyun Kim
Journal:  Korean J Anesthesiol       Date:  2011-09-23

Review 3.  Systematic review of near-infrared spectroscopy determined cerebral oxygenation during non-cardiac surgery.

Authors:  Henning B Nielsen
Journal:  Front Physiol       Date:  2014-03-17       Impact factor: 4.566

4.  Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position.

Authors:  Ji-Hyun Chin; Hyungseok Seo; Eun-Ho Lee; Joohyun Lee; Jun Hyuk Hong; Jai-Hyun Hwang; Young-Kug Kim
Journal:  BMC Anesthesiol       Date:  2015-03-31       Impact factor: 2.217

5.  Cerebral oxygenation in 45-degree trendelenburg position for robot-assisted radical prostatectomy: a single-center, open, controlled pilot study.

Authors:  Clemens Wiesinger; Dominik Stefan Schoeb; Mathias Stockhammer; Emir Mirtezani; Lukas Mitterschiffthaler; Helga Wagner; Johann Knotzer; Walter Pauer
Journal:  BMC Urol       Date:  2020-12-30       Impact factor: 2.264

6.  Retrospective evaluation of the effect of carotid artery stenosis on cerebral oxygen saturation during off-pump coronary artery bypasses grafting in adult patients.

Authors:  S Toyama; K Matsuoka; Y Tagaito; M Shimoyama
Journal:  BMC Anesthesiol       Date:  2015-12-15       Impact factor: 2.217

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.